Herein we describe a procedure for the in situ cyanogen bromide cleavage of N-terminally blocked proteins which have been immobilised onto the glass fiber sample disk of the gas-phase sequencer. In this manner, new amino terminii suitable for automated Edman degradation can be generated. Cytochrome C was cleaved using this method on the carboxyl side of methionine residues 65 and 80. This allowed sequence analysis to begin simultaneously at residues 66 and 81 (Table 1). This procedure offers an alternative sequencing tactic for methionine-containing proteins which are N-terminally blocked.

摘要

在此,我们描述了一种用于原位溴化氰裂解已固定在气相测序仪玻璃纤维样品盘上的N端封闭蛋白质的方法。通过这种方式,可以产生适合自动埃德曼降解的新氨基末端。使用该方法在甲硫氨酸残基65和80的羧基侧对细胞色素C进行了裂解。这使得序列分析能够同时从残基66和81开始(表1)。该方法为N端封闭的含甲硫氨酸蛋白质提供了一种替代的测序策略。