Joo H S, Molitor T W, Leman A D
Am J Vet Res. 1984 Oct;45(10):2096-8.
A radial immunodiffusion enzyme assay for the detection and quantitation of antibodies to pseudorabies virus in swine sera was developed and the methods were standardized. The assay combined the principle of radial immunodiffusion with enzyme-linked immunosorbent assay. Quantitation of pseudorabies virus antibody titers was determined by measuring the diameter of a colored circular zone after overnight incubation of antibody with antigen. The specificity and sensitivity of the radial immunodiffusion enzyme assay were compared with that of the standard virus-neutralization test, and the results were determined to be correlated highly (r = 0.694, P less than 0.0001). The assay also appeared to be highly reproducible and simple to perform.
开发了一种用于检测和定量猪血清中伪狂犬病病毒抗体的放射免疫扩散酶测定法,并对方法进行了标准化。该测定法将放射免疫扩散原理与酶联免疫吸附测定相结合。通过在抗体与抗原过夜孵育后测量有色圆形区域的直径来确定伪狂犬病病毒抗体滴度的定量。将放射免疫扩散酶测定法的特异性和敏感性与标准病毒中和试验进行了比较,结果确定具有高度相关性(r = 0.694,P小于0.0001)。该测定法似乎还具有高度可重复性且易于操作。