Ballantine J, Woolfson A D
J Pharm Pharmacol. 1980 May;32(5):353-6. doi: 10.1111/j.2042-7158.1980.tb12935.x.
Differential pulse voltammetry at the glassy carbon electrode has been applied to the determination of ascorbic acid, pyridoxine and folic acid in a multivitamin preparation. The individual vitamins all gave well-defined peaks in the anodic region with a linear response of peak current to concentration. The water-soluble vitamins were extracted into aqueous solution and folic acid into dibasic potassium phosphate solution. Before determination of pyridoxine, the ascorbic acid peak was depressed by reaction with formaldehyde. Iron (II) present in the multivitamin preparation did not interfere with the analysis. The voltammetric method compared favourably in terms of accuracy and precision with official methods: it was found to be much simpler, with sample manipulation kept to a minimum. The method was found to be generally applicable to the determination of the vitamins in several multivitamin preparations, or, in simplified form, to the determination of the individual vitamin preparations.
玻碳电极上的微分脉冲伏安法已用于测定多种维生素制剂中的抗坏血酸、吡哆醇和叶酸。每种维生素在阳极区域均给出明确的峰,峰电流对浓度呈线性响应。水溶性维生素被萃取到水溶液中,叶酸被萃取到磷酸氢二钾溶液中。在测定吡哆醇之前,抗坏血酸峰通过与甲醛反应而降低。多种维生素制剂中存在的铁(II)不干扰分析。伏安法在准确度和精密度方面与官方方法相比具有优势:它被发现要简单得多,样品处理保持在最低限度。该方法被发现通常适用于测定多种维生素制剂中的维生素,或者以简化形式适用于测定单个维生素制剂。