Wellby M L, Guthrie L, Reilly C P
Clin Chem. 1981 Dec;27(12):2022-4.
The Amerlex Free Thyroxin (T4) Radioimmunoassay Kit (Amersham International Ltd.) is a new direct equilibrium radioimmunoassay for free T4 based on an antiserum with very high affinity for T4, and a unique 125I-labeled T4 analog as tracer. It is a very simple single-tube radioimmunoassay, making use of Amerlex particles to separate antibody-bound from free species. Interassay precision (CV) is 3.7% at 13 pmol/L and 2.3% at 30 pmol/L; within-assay precision is 4.2% at 21 pmol/L. The reference interval is 11-22 pmol/L. The assay did not misclassify any patients tested who had untreated myxedema or untreated thyrotoxicosis. The free T4 assay excelled both the free T4 index and the T4/T4-binding globulin ratio in correcting for increased thyroxin-binding globulin from pregnancy, and it was better than the index but not better than the ratio in correcting for increased thyroxin-binding globulin in users of oral contraceptives.
Amerlex游离甲状腺素(T4)放射免疫分析试剂盒(阿默沙姆国际有限公司)是一种新型的游离T4直接平衡放射免疫分析方法,它基于对T4具有极高亲和力的抗血清,以及一种独特的125I标记的T4类似物作为示踪剂。这是一种非常简单的单管放射免疫分析方法,利用Amerlex颗粒分离结合抗体的物质和游离物质。批间精密度(CV)在13 pmol/L时为3.7%,在30 pmol/L时为2.3%;批内精密度在21 pmol/L时为4.2%。参考区间为11 - 22 pmol/L。该分析方法对任何未经治疗的黏液性水肿或甲状腺毒症患者的检测结果均未出现误判。在纠正因妊娠导致的甲状腺素结合球蛋白增加方面,游离T4分析优于游离T4指数和T4/甲状腺素结合球蛋白比值;在纠正口服避孕药使用者甲状腺素结合球蛋白增加方面,它优于游离T4指数,但不比T4/甲状腺素结合球蛋白比值更好。