Serum free thyroxin (FT4) in normal nonpregnant and pregnant subjects was measured by radioimmunoassay (RIA) with Amerlex FT4 RIA (Amersham International) and LiquiSol FT4 RIA (Damon Diagnostics) kits. Amerlex FT4 values in serum from pregnant women were lower than those in serum from nonpregnant women, but LiquiSol FT4 values were similar in serum from both groups. Amerlex FT4 values were directly correlated with the concentrations of albumin in serum and inversely correlated with those of thyroxin-binding globulin, but not with prealbumin concentrations. No significant correlations were observed between LiquiSol FT4 values and serum concentrations of thyroxin-binding proteins. Amerlex FT4 values were normal in patients with excess, deficient, or decreased thyroxin-binding globulin. Albumin added to serum samples increased Amerlex FT4 values but not LiquiSol FT4 values. Albumin inhibited the binding of labeled thyroxin analog to the solid-phase thyroxin antibody. These data indicate that the albumin concentration influences FT4 values as measured by an RIA involving a thyroxin analog and that Amerlex FT4 values should be carefully interpreted when the patient has an abnormal concentration of serum albumin.
采用Amerlex FT4放射免疫分析试剂盒(阿默沙姆国际公司)和LiquiSol FT4放射免疫分析试剂盒(达蒙诊断公司),通过放射免疫分析法(RIA)测定正常非妊娠和妊娠受试者血清中的游离甲状腺素(FT4)。孕妇血清中的Amerlex FT4值低于非孕妇血清中的值,但两组血清中的LiquiSol FT4值相似。Amerlex FT4值与血清中白蛋白浓度呈正相关,与甲状腺素结合球蛋白浓度呈负相关,但与前白蛋白浓度无关。未观察到LiquiSol FT4值与甲状腺素结合蛋白血清浓度之间存在显著相关性。甲状腺素结合球蛋白过多、不足或减少的患者,其Amerlex FT4值正常。向血清样本中添加白蛋白可增加Amerlex FT4值,但不增加LiquiSol FT4值。白蛋白抑制标记甲状腺素类似物与固相甲状腺素抗体的结合。这些数据表明,白蛋白浓度会影响通过涉及甲状腺素类似物的放射免疫分析法测定的FT4值,当患者血清白蛋白浓度异常时,应谨慎解读Amerlex FT4值。