Dal Bo Zanon R, Gazzetta R, Patrassi G, Stocco D, Girolami A
Folia Haematol Int Mag Klin Morphol Blutforsch. 1983;110(6):874-8.
Factor IX: C activity decay was studied in lyophilized concentrates (Bebulin, IMMUNO) stored at room temperature and in reconstituted preparations frozen and stored at -20 degrees C. A very slight, practically identical, decay of Factor IX: C was found in lyophilized concentrates kept at room temperature, in reconstituted lyophilized concentrates frozen and stored at -20 degrees C and lyophilized concentrates kept at +4 degrees C. At the end of the experiment, which was 4-5 months after the expiration date of the product, a 15-30% decay of Factor IX: C could be found in the concentrates with respect to initial levels.
对在室温下储存的冻干浓缩物(贝布灵、免疫)以及复溶制剂在-20℃冷冻储存时的凝血因子IX:C活性衰减情况进行了研究。发现在室温下保存的冻干浓缩物、在-20℃冷冻储存的复溶冻干浓缩物以及在+4℃保存的冻干浓缩物中,凝血因子IX:C的衰减非常轻微,几乎相同。在产品有效期过后4 - 5个月的实验结束时,浓缩物中的凝血因子IX:C相对于初始水平出现了15 - 30%的衰减。