Hepatic arterial perfusion scintigraphy with Tc-99m-MAA. Use of a totally implanted drug delivery system.

作者信息

Ziessman H A, Thrall J H, Yang P J, Walker S C, Cozzi E A, Niederhuber J E, Gyves J W, Ensminger W D, Tuscan M C

出版信息

Radiology. 1984 Jul;152(1):167-72. doi: 10.1148/radiology.152.1.6233632.

Abstract

Tc-99m-MAA hepatic arterial perfusion scintigraphy ( HAPS ) using a totally implanted drug delivery system was employed for hepatic arterial chemotherapy in 147 patients (335 studies). Complete perfusion of the involved liver was seen in 88% of patients initially [more so in those with normal hepatic vascular anatomy (93%) than those with vascular variants (79%)] and remained good on follow-up. In 67 consecutive patients (95 studies), arteriovenous shunting to the lung ranged from 0.4 to 32% (mean, 6.2% +/- 4.1 S.D.). Uptake at the tip of the catheter was increased in 20% of patients, but good perfusion was usually maintained. A significant decrease in hepatic and/or extrahepatic perfusion associated with a "hot spot" at the tip of the catheter indicated hepatic arterial thrombosis. Extrahepatic perfusion was seen in 14% of cases, usually in the distribution of the stomach, small bowel, and spleen. Significant symptoms of drug toxicity were seen in 70% of patients with extrahepatic perfusion, compared to 19% of those without it.