Dharmarajan V, Rando R J
Am Ind Hyg Assoc J. 1980 Dec;41(12):869-78. doi: 10.1080/15298668091425798.
This paper describes the experiments and the results of an exhaustive and critical laboratory study which evaluated the performance of continuous area and personal monitors popularly used in measuring the concentrations of TDI in industrial environments. The studies consisted of dynamic calibrations, the effect of humidity and temperature on the measurements, and the interferences due to commonly encountered contaminants in a TDI manufacturing plant. The response and resolution of the personal monitor for short-term fluctuations of TDI concentration in time and space are also reported.
本文描述了一项详尽且关键的实验室研究的实验及结果,该研究评估了工业环境中常用于测量甲苯二异氰酸酯(TDI)浓度的连续区域监测仪和个人监测仪的性能。这些研究包括动态校准、湿度和温度对测量的影响,以及TDI制造工厂中常见污染物引起的干扰。文中还报告了个人监测仪对TDI浓度在时间和空间上短期波动的响应及分辨率。