Sasaki H
Tohoku J Exp Med. 1980 Dec;132(4):405-11. doi: 10.1620/tjem.132.405.
The vascular anastomosis free of suture was made by using an absorbable suture and its tensile strength was compared with that of non-absorbable suture anastomosis. 29 adult mongrel dogs weighing 7.5 to 13.5 kg were used. Two kinds of vascular anastomosis were performed, that is, artery-to-artery anastomosis and vascular prosthetic graft to artery anastomosis. They were made in the right carotid artery and the abdominal aorta, respectively. Two kinds of suture were used for the vascular anastomosis, i.e., polyglycolic acid suture as an absorbable suture and TEVDEK suture as a non-absorbable suture. The tensile strength of anastomosis was measured by a self-made tensiometer. The following results were obtained: In the artery-to-artery anastomosis, the loss of the strength of suture did not weaken the anastomosis, whereas in the vascular prosthetic anastomosis, the loss of the tensile strength of suture weakened the vascular prosthetic anastomosis. However, well organized fibrous tissues surrounding the vascular prosthesis were strong enough to hold against the blood pressure.
使用可吸收缝线进行无缝线血管吻合,并将其抗张强度与不可吸收缝线吻合的抗张强度进行比较。使用了29只体重在7.5至13.5千克之间的成年杂种犬。进行了两种血管吻合,即动脉对动脉吻合和血管假体移植物对动脉吻合。它们分别在右颈动脉和腹主动脉中进行。血管吻合使用了两种缝线,即作为可吸收缝线的聚乙醇酸缝线和作为不可吸收缝线的TEVDEK缝线。吻合的抗张强度通过自制张力计测量。得到以下结果:在动脉对动脉吻合中,缝线强度的损失并未削弱吻合,而在血管假体吻合中,缝线抗张强度的损失削弱了血管假体吻合。然而,血管假体周围组织良好的纤维组织足以抵抗血压。