Rozen P, Gelfond M, Zaltzman S, Baron J, Gilat T
Radiology. 1982 Aug;144(3):587-90. doi: 10.1148/radiology.144.3.6285414.
The esophagus was evaluated in 15 patients with achalasia by continuous gamma camera imaging following ingestion of a semi-solid meal labeled with 99mTc. The images were displayed and recorded on a simple computerized data processing/display system. Subsequent ciné mode images of esophageal emptying demonstrated abnormalities of the body of the esophagus not reflected by the manometric examination. Computer-generated time-activity curves representing specific regions of interest were better than manometry in evaluating the results of myotomy, dilatation, and drug therapy. Isosorbide dinitrate significantly improved esophageal emptying.
对15例贲门失弛缓症患者,在摄入用99mTc标记的半固体餐食后,通过连续γ相机成像对食管进行评估。图像在一个简单的计算机化数据处理/显示系统上显示并记录。随后的食管排空电影模式图像显示出食管体部的异常,而测压检查未反映出这些异常。在评估肌切开术、扩张术和药物治疗的结果时,代表特定感兴趣区域的计算机生成的时间-活性曲线比测压更好。硝酸异山梨酯显著改善了食管排空。