Cohen D, Appel G B, Scully B, Neu H C
Antimicrob Agents Chemother. 1983 Oct;24(4):529-32. doi: 10.1128/AAC.24.4.529.
The pharmacokinetic parameters of ceftriaxone in eight patients with end-stage renal disease were determined during dialysis and during the interdialysis period. The mean half-life, clearance, and apparent volume of distribution during dialysis were 16 h, 722 ml/h, and 16.7 liters, respectively. During the interdialysis period, the half-life was 14 h, clearance was 739 ml/h, and volume of distributions was 14 liters. Individual variability in plasma concentrations occurred even in patients with apparently normal hepatic function. Based on these parameters, a dose of 1 g every 24 h would yield concentrations in excess of the concentrations needed to inhibit most gram-positive and gram-negative aerobic species.
在透析期间和透析间期测定了8例终末期肾病患者头孢曲松的药代动力学参数。透析期间的平均半衰期、清除率和表观分布容积分别为16小时、722毫升/小时和16.7升。在透析间期,半衰期为14小时,清除率为739毫升/小时,分布容积为14升。即使在肝功能明显正常的患者中,血浆浓度也存在个体差异。根据这些参数,每24小时1克的剂量会使浓度超过抑制大多数革兰氏阳性和革兰氏阴性需氧菌所需的浓度。