Pettipher G L, Fulford R J, Mabbitt L A
J Appl Bacteriol. 1983 Apr;54(2):177-82. doi: 10.1111/j.1365-2672.1983.tb02604.x.
The direct epifluorescent filter technique (DEFT) is a new rapid method which uses membrane filtration and epifluorescent microscopy for counting in milk. A collaborative trial of the DEFT was conducted between six laboratories. Each laboratory obtained a highly significant relationship between the DEFT count and plate count with a correlation coefficient generally greater than 0.9 but there were significant differences between these relationships. The repeatability of the DEFT, although ca 1.5 times worse than that of the plate count, was of a level acceptable in practice. Reproducibility of the DEFT was ca 3 times that of the plate count. This poor reproducibility was probably mainly due to counting errors. Possible reasons for this and ways of reducing counting errors are discussed.
直接荧光滤膜技术(DEFT)是一种新的快速方法,它利用膜过滤和落射荧光显微镜对牛奶进行计数。六个实验室之间进行了DEFT的协同试验。每个实验室在DEFT计数和平板计数之间都获得了高度显著的关系,相关系数通常大于0.9,但这些关系之间存在显著差异。DEFT的重复性虽然比平板计数差约1.5倍,但在实际中处于可接受的水平。DEFT的再现性约为平板计数的3倍。这种较差的再现性可能主要是由于计数误差。本文讨论了造成这种情况的可能原因以及减少计数误差的方法。