A Bactometer model 32 was evaluated for use in early detection of bacterial growth. Experiments with simulated cultures showed that 2 ml of broth introduced into the Bactometer module wells could detect 10(2) and 10(6) CFU/ml in 6 h and 2 h respectively. Both Brain Heart Infusion (BHI) and Fastidious Anaerobic broths supported good growth. Detection of nine of 10 organisms inoculated at approximately 10(6) CFU/ml in BHI were detected within 8.5 h. A culture of Bacteroides fragilis failed to grow under these conditions. Of 189 blood cultures, tested by incubation of 2 ml of BHI, 18 were positive by both conventional and Bactometer methods. False-positive or false-negative specimens were not observed using the Bactometer. Use of the Bactometer enables growth detection at least 12 h earlier than culture methods.
对一台32型细菌计数仪进行了评估,以用于细菌生长的早期检测。模拟培养实验表明,引入细菌计数仪模块孔中的2毫升肉汤分别可在6小时和2小时内检测到每毫升10²和10⁶个菌落形成单位(CFU)。脑心浸液(BHI)肉汤和苛求厌氧菌肉汤都能支持良好的生长。在BHI肉汤中以约每毫升10⁶个CFU接种的10种微生物中有9种在8.5小时内被检测到。脆弱拟杆菌培养物在这些条件下未能生长。在通过对2毫升BHI肉汤进行培养测试的189份血培养物中,有18份通过传统方法和细菌计数仪方法均呈阳性。使用细菌计数仪未观察到假阳性或假阴性标本。使用细菌计数仪能够比培养方法至少提前12小时检测到细菌生长。