An improved microsurgical technique for orthotopic rat kidney transplantation is described in detail. (1) End-to-end anastomosis of renal arteries with 7-8 interrupted 10-0 sutures. (2) End-to-end anastomosis of renal veins with 2 continuous semicircular 10-0 sutures. (3) Non-splinted end-to-end ureteric anastomosis with 4 interrupted full-thickness 11-0 sutures. (4) Simultaneous bilateral nephrectomy. Seventy transplantations were analysed. No failure due to complications of the vascular anastomoses occurred. The ureteric anastomoses were complicated by stenosis in only 5 animals (7%). The operation times for vascular anastomoses were 20 (15-24) minutes and for complete transplantation 50 (45-60) minutes. This technique seems to be less time consuming than other methods. Our method has produced a success rate of 93% with well standardized and reproducible organ quality. Preliminary clinical experiences with extracorporeal microvascular reconstruction in 4 cases of injured small polar kidney allograft arteries support the continued application in appropriate situations to increase the number of suitable donor kidneys.
详细描述了一种改良的大鼠原位肾移植显微外科技术。(1) 用7-8针间断的10-0缝线进行肾动脉端端吻合。(2) 用2针连续半圆形的10-0缝线进行肾静脉端端吻合。(3) 用4针间断全层11-0缝线进行无支撑的输尿管端端吻合。(4) 同期双侧肾切除术。分析了70例移植手术。未发生因血管吻合并发症导致的失败。仅5只动物(7%)出现输尿管吻合口狭窄并发症。血管吻合的手术时间为20(15-24)分钟,完整移植的手术时间为50(45-60)分钟。该技术似乎比其他方法耗时更少。我们的方法成功率为93%,器官质量标准化且可重复。4例小极肾移植动脉损伤患者进行体外微血管重建的初步临床经验支持在适当情况下继续应用该技术,以增加合适供肾的数量。