Suppr超能文献

肝血流测量 三、在犬脓毒症休克模型中通过吲哚菁绿清除率和电磁流量计测量的肝总血流量。

Hepatic blood flow measurement III. Total hepatic blood flow measured by ICG clearance and electromagnetic flowmeters in a canine septic shock model.

作者信息

Nxumalo J L, Teranaka M, Schenk W G

出版信息

Ann Surg. 1978 Mar;187(3):299-302. doi: 10.1097/00000658-197803000-00015.

Abstract

The validity of the ICG clearance method for the measurement of THBF in abnormal circulatory states remains questionable. In this study THBF measured by this method is compared with the electromagnetic flow technique in a canine spetic model. Good correlation is demonstrated between the two in normal control animals. However, in the septic animals the ICG underestimated the electromagnetic flow result by 20%. This is true in both the high and the low cardiac output septic shock pictures that emerge. In the septic animals, the total hepatic blood flow as measured by the ICG was almost equal to the portal vein flow alone measured by the electromagnetic flowmeters suggesting that this was the quantity it was measuring in this abnormal state. Pathophysiologic mechanisms that may explain the discrepancy are given.

摘要

吲哚菁绿清除法用于测量异常循环状态下的肝血流量(THBF)的有效性仍存在疑问。在本研究中,在犬脓毒症模型中,将用该方法测量的THBF与电磁血流技术进行了比较。在正常对照动物中,二者显示出良好的相关性。然而,在脓毒症动物中,吲哚菁绿法测得的结果比电磁血流技术的结果低20%。在出现的高心输出量和低心输出量脓毒症休克情况中均是如此。在脓毒症动物中,用吲哚菁绿法测得的总肝血流量几乎等于仅用电磁流量计测得的门静脉血流量,这表明这就是该方法在这种异常状态下所测量的量。文中给出了可能解释这种差异的病理生理机制。

相似文献

本文引用的文献

7
Liver in septic shock.脓毒性休克中的肝脏。
Am J Gastroenterol. 1973 Mar;59(3):250-4.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验