Suppr超能文献

一种快速菌尿筛查仪器的评估

Evaluation of a rapid bacteriuria screening instrument.

作者信息

Cashman J S, Ahlin P A, Matsen J M

出版信息

Diagn Microbiol Infect Dis. 1984 Jan;2(1):11-6. doi: 10.1016/0732-8893(84)90018-x.

Abstract

A newly modified, semiautomated instrument (Bacteriuria detection device (BDD] designed to detect the presence of bacteriuria in less than 3 min was compared to quantitative urine culture plating techniques. The instrument consists of a self-enclosed vacuum-filtration-staining system in which a 1-ml urine filtrate is stained on a filter. The resulting color determines the quantitation. Of the total of 525 clinical urine specimens tested, 66 (12.6%) were uninterpretable due to pigment deposition or inability to complete the filtering process (clogging of the filter). Of the remaining 459 specimens, 93 (20.3%) had a plate quantitation colony count of 10(5) colony-forming units (CFU)/ml or more. The BDD detected 94.2% of these positive specimens if only significant pathogens were included (85% if specimens that were probably contaminated were also included). For specimens containing significant pathogens at 10(4)-10(5) CFU/ml, the BDD detection rate was 41%. The device detected most (94.3%) gram-negative bacilli and enterococci at colony counts of 10(5) CFU/ml or more. In addition, the BDD accurately detected 95.6% of specimens with no growth or fewer than 10(4) CFU/ml. With several proposed modifications, these results suggest that this instrument is potentially useful as a urine screening device in a select population.

摘要

一种新改良的半自动仪器(细菌尿检测装置[BDD])被设计用于在不到3分钟内检测细菌尿的存在,并与定量尿培养平板技术进行了比较。该仪器由一个自封闭的真空过滤染色系统组成,在该系统中,1毫升尿液滤液在滤膜上染色。最终的颜色决定定量结果。在总共检测的525份临床尿液标本中,66份(12.6%)由于色素沉积或无法完成过滤过程(滤膜堵塞)而无法解读。在其余459份标本中,93份(20.3%)的平板定量菌落计数为10⁵菌落形成单位(CFU)/毫升或更高。如果仅包括重要病原体,BDD检测出这些阳性标本中的94.2%(如果也包括可能被污染的标本,则为85%)。对于含有10⁴ - 10⁵CFU/毫升重要病原体的标本,BDD检测率为41%。该装置在菌落计数为10⁵CFU/毫升或更高时检测出大多数(94.3%)革兰氏阴性杆菌和肠球菌。此外,BDD准确检测出95.6%无生长或少于10⁴CFU/毫升的标本。通过一些提议的改进,这些结果表明该仪器在特定人群中作为尿液筛查装置可能具有实用性。

相似文献

1
Evaluation of a rapid bacteriuria screening instrument.一种快速菌尿筛查仪器的评估
Diagn Microbiol Infect Dis. 1984 Jan;2(1):11-6. doi: 10.1016/0732-8893(84)90018-x.
2
Clinical laboratory evaluation of a urine screening device.尿液筛查设备的临床实验室评估
J Clin Microbiol. 1983 Sep;18(3):674-9. doi: 10.1128/jcm.18.3.674-679.1983.
5
Colorimetric method for rapid determination of bacteriuria.快速测定菌尿症的比色法。
J Clin Microbiol. 1981 Sep;14(3):342-6. doi: 10.1128/jcm.14.3.342-346.1981.
6
Evaluation of the Bacteriuria Detection Device.细菌尿检测装置的评估
J Clin Microbiol. 1983 Oct;18(4):882-4. doi: 10.1128/jcm.18.4.882-884.1983.
10
Evaluation of a two-minute test for urine screening.尿液筛查两分钟测试的评估
J Clin Microbiol. 1983 Sep;18(3):697-701. doi: 10.1128/jcm.18.3.697-701.1983.