Suppr超能文献

采用URISCREEN快速酶促筛查试验检测菌尿和脓尿。

Detection of bacteriuria and pyuria by URISCREEN a rapid enzymatic screening test.

作者信息

Pezzlo M T, Amsterdam D, Anhalt J P, Lawrence T, Stratton N J, Vetter E A, Peterson E M, de la Maza L M

机构信息

Department of Pathology, University of California Irvine Medical Center, Orange 92668.

出版信息

J Clin Microbiol. 1992 Mar;30(3):680-4. doi: 10.1128/jcm.30.3.680-684.1992.

Abstract

A multicenter study was performed to evaluate the ability of the URISCREEN (Analytab Products, Plainview, N.Y.), a 2-min catalase tube test, to detect bacteriuria and pyuria. This test was compared with the Chemstrip LN (BioDynamics, Division of Boehringer Mannheim Diagnostics, Indianapolis, Ind.), a 2-min enzyme dipstick test; a semiquantitative plate culture method was used as the reference test for bacteriuria, and the Gram stain or a quantitative chamber count method was used as the reference test for pyuria. Each test was evaluated for its ability to detect probable pathogens at greater than or equal to 10(2) CFU/ml and/or greater than or equal to 1 leukocyte per oil immersion field, as determined by the Gram stain method, or greater than 10 leukocytes per microliter, as determined by the quantitative count method. A total of 1,500 urine specimens were included in this evaluation. There were 298 specimens with greater than or equal 10(2) CFU/ml and 451 specimens with pyuria. Of the 298 specimens with probable pathogens isolated at various colony counts, 219 specimens had colony counts of greater than or equal to 10(5) CFU/ml, 51 specimens had between 10(4) and 10(5) CFU/ml, and 28 specimens had between 10(2) and less than 10(4) CFU/ml. Both the URISCREEN and the Chemstrip LN detected 93% (204 of 219) of the specimens with probable pathogens at greater than or equal to 10(5) CFU/ml. For the specimens with probable pathogens at greater than or equal to 10(2) CFU/ml, the sensitivities of the URISCREEN and the Chemstrip LN were 86% (256 of 298) and 81% (241 of 298), respectively. Of the 451 specimens with pyuria, the URISCREEN detected 88% (398 of 451) and Chemstrip LN detected 78% (350 if 451). There were 204 specimens with both greater than or equal to 10(2) CFU/ml and pyuria; the sensitivities of both methods were 95% (193 of 204) for these specimens. Overall, there were 545 specimens with probable pathogens at greater than or equal to 10(2) CFU/ml and/or pyuria. The URISCREEN detected 85% (461 of 545), and the Chemstrip LN detected 73% (398 of 545). A majority (76%) of the false-negative results obtained with either method were for specimens without leukocytes in the urine. There were 955 specimens with no probable pathogens or leukocytes. Of these, 28% (270 of 955) were found positive by the URISCREEN and 13% (122 of 955) were found positive by the Chemstrip LN. A majority of the false-positive results were probably due, in part, to the detection of enzymes present in both bacterial and somatic cells by each of the test systems. Overall, the URISCREEN is rapid, manual, easy-to-perform enzymatic test that yields findings similar to those yielded by the Chemstrip LN for specimens with both greater than or equal to 10(2) CFU/ml and pyuria or for specimens with greater than or equal to 10(5) CFU/ml and with or without pyuria. However, when the data were analyzed for either probable pathogens at less 10(5) CFU/ml or pyuria, the sensitivity of the URISCREEN was higher (P less than 0.05).

摘要

进行了一项多中心研究,以评估URISCREEN(Analytab Products公司,纽约州普莱恩维尤)这种需时2分钟的过氧化氢酶试管试验检测菌尿和脓尿的能力。该试验与Chemstrip LN(生物动力学公司,勃林格殷格翰诊断公司分部,印第安纳州印第安纳波利斯)这种需时2分钟的酶试纸条试验进行比较;采用半定量平板培养法作为菌尿的参考试验,革兰氏染色或定量计数室法作为脓尿的参考试验。评估了每种试验检测革兰氏染色法确定的每油镜视野大于或等于10²CFU/ml和/或大于或等于1个白细胞,或定量计数法确定的每微升大于10个白细胞的可能病原体的能力。本评估共纳入1500份尿液标本。有298份标本每毫升菌落数大于或等于10²CFU/ml,451份标本有脓尿。在298份分离出不同菌落数的可能病原体的标本中,219份标本的菌落数大于或等于10⁵CFU/ml,51份标本的菌落数在10⁴至10⁵CFU/ml之间,28份标本的菌落数在10²至小于10⁴CFU/ml之间。URISCREEN和Chemstrip LN均检测出93%(219份中的204份)每毫升菌落数大于或等于10⁵CFU/ml的可能病原体标本。对于每毫升菌落数大于或等于10²CFU/ml的可能病原体标本,URISCREEN和Chemstrip LN的灵敏度分别为86%(298份中的256份)和81%(298份中的241份)。在451份有脓尿的标本中,URISCREEN检测出88%(451份中的398份),Chemstrip LN检测出78%(451份中的350份)。有204份标本每毫升菌落数大于或等于10²CFU/ml且有脓尿;两种方法对这些标本的灵敏度均为95%(204份中的193份)。总体而言,有545份标本每毫升菌落数大于或等于10²CFU/ml和/或有脓尿。URISCREEN检测出85%(545份中的461份),Chemstrip LN检测出73%(545份中的398份)。两种方法获得的大多数(76%)假阴性结果是针对尿液中无白细胞的标本。有955份标本无可能病原体或白细胞。其中,28%(955份中的270份)被URISCREEN检测为阳性,13%(955份中的122份)被Chemstrip LN检测为阳性。大多数假阳性结果可能部分归因于每个检测系统检测细菌和体细胞中存在的酶。总体而言,URISCREEN是一种快速、手动、易于操作的酶试验,对于每毫升菌落数大于或等于10²CFU/ml且有脓尿的标本,或每毫升菌落数大于或等于10⁵CFU/ml且有或无脓尿的标本,其结果与Chemstrip LN相似。然而,当分析每毫升菌落数小于10⁵CFU/ml的可能病原体或脓尿的数据时,URISCREEN的灵敏度更高(P小于0.05)。

相似文献

2
Detection of bacteriuria and pyuria within two minutes.两分钟内检测出菌尿和脓尿。
J Clin Microbiol. 1985 Apr;21(4):578-81. doi: 10.1128/jcm.21.4.578-581.1985.
3
Rapid bioluminescence method for bacteriuria screening.用于菌尿筛查的快速生物发光法
J Clin Microbiol. 1989 Apr;27(4):716-20. doi: 10.1128/jcm.27.4.716-720.1989.
9
Evaluation of the FiltraCheck-UTI for detection of bacteriuria.
Diagn Microbiol Infect Dis. 1990 Jul-Aug;13(4):289-95. doi: 10.1016/0732-8893(90)90019-r.

引用本文的文献

本文引用的文献

1
Diagnosis of coliform infection in acutely dysuric women.急性排尿困难女性大肠菌感染的诊断
N Engl J Med. 1982 Aug 19;307(8):463-8. doi: 10.1056/NEJM198208193070802.
2
Causes of the acute urethral syndrome in women.女性急性尿道综合征的病因。
N Engl J Med. 1980 Aug 21;303(8):409-15. doi: 10.1056/NEJM198008213030801.
3
Detection of bacteriuria and pyuria within two minutes.两分钟内检测出菌尿和脓尿。
J Clin Microbiol. 1985 Apr;21(4):578-81. doi: 10.1128/jcm.21.4.578-581.1985.
5
Diagnosis and treatment of acute urinary tract infections.
Infect Dis Clin North Am. 1987 Dec;1(4):773-91.
6
Detection of urinary tract infections by rapid methods.通过快速方法检测尿路感染
Clin Microbiol Rev. 1988 Jul;1(3):268-80. doi: 10.1128/CMR.1.3.268.
7
Urinary tract infections in women: diagnosis and treatment.女性尿路感染:诊断与治疗
Ann Intern Med. 1989 Dec 1;111(11):906-17. doi: 10.7326/0003-4819-111-11-906.
8
Rapid bioluminescence method for bacteriuria screening.用于菌尿筛查的快速生物发光法
J Clin Microbiol. 1989 Apr;27(4):716-20. doi: 10.1128/jcm.27.4.716-720.1989.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验