Suppr超能文献

铟-111 奥克辛自体标记血小板在肾移植排斥反应诊断中的应用

In-111 oxine autologous labeled platelets in the diagnosis of kidney graft rejection.

作者信息

Martin-Comin J, Roca M, Griño J M, Paradell C, Caralps C

出版信息

Clin Nucl Med. 1983 Jan;8(1):7-10. doi: 10.1097/00003072-198301000-00003.

Abstract

The usefulness of In-111 oxine labeled autologous platelets in the diagnosis of renal graft rejection was studied. The method is based on imaging of the graft area at 4, 24, 48, and 72 hours after the injection of the labeled cells. The study was done in 31 renal transplant recipients. The control group included four patients with normal renal function without evidence of rejection. No platelet uptake was observed in any of them. The study group included 22 patients with acute rejection which was confirmed histologically in 13. One case of chronic vascular type rejection of the graft tracer uptake was seen. There was a false-positive result due to a perirenal hematoma. In three patients with a non-immunological sudden impairment of renal function, no activity was detected in the graft area. We also evaluated the changes in platelet trapping throughout the study and they seemed to correlate with the response to the antirejection therapy.

摘要

研究了铟 - 111 奥克辛标记的自体血小板在肾移植排斥反应诊断中的效用。该方法基于在注射标记细胞后 4 小时、24 小时、48 小时和 72 小时对移植区域进行成像。该研究在 31 名肾移植受者中进行。对照组包括 4 名肾功能正常且无排斥反应证据的患者。在他们任何一人中均未观察到血小板摄取。研究组包括 22 例急性排斥反应患者,其中 13 例经组织学证实。观察到 1 例移植示踪剂摄取的慢性血管型排斥反应病例。由于肾周血肿出现了 1 例假阳性结果。在 3 例肾功能非免疫性突然受损的患者中,移植区域未检测到活性。我们还评估了整个研究过程中血小板捕获的变化,它们似乎与抗排斥治疗的反应相关。