Raffin T, Bringuier J P, Veysseyre C M, Trepo C, Lamelin J P
J Immunol Methods. 1983 Mar 11;58(1-2):155-70. doi: 10.1016/0022-1759(83)90272-7.
A micromethod for the solid-phase conglutinin binding assay (Con BA) for the detection of circulating immune complexes (CIC) is described, in which the use of microplates, glucose oxidase-coupled anti-human immunoglobulins and automatic OD recorder contributed to the speed and low cost of this reproducible and sensitive test. The Con BA values of a large population of healthy blood donors had a wide distribution which in our series of 189 appeared to be trimodal. The Con BA values clearly reflected the levels of the main Ig classes (M, G, and A). This was confirmed by follow up of 6 individuals with high initial Con BA values. For 4 of them, a parallel decrease in Con BA value and IgG concentration was observed. In the 2 others, the sustained high level of Con BA remained unexplained. Complement components and activity of these sera were within normal limits. Because of fluctuation in the aggregated human gamma-globulins (AHG) reference curve, expression of results was based upon the standard deviation of 6 normal sera. In view of the above results, these sera were selected from those with the lowest Con BA values. On the basis that Con BA and C1q BA may detect CIC differing in their ag/ab ratio, sera from rheumatoid arthritis and chronic active B hepatitis patients with or without conventional rheumatoid factors (RF) were analyzed by both Con BA and C1q BA. RF-containing sera, likely to contain CIC in antigen excess, contributed exclusively to the highest C1q BA and lowest Con BA values. In contrast C1q BA-Con BA+ sera were preferentially RF negative. It is proposed that the complexes thus detected may be of idiotype-anti-idiotype nature.
本文描述了一种用于检测循环免疫复合物(CIC)的固相凝集素结合试验(Con BA)的微量方法,其中使用微孔板、葡萄糖氧化酶偶联的抗人免疫球蛋白和自动OD记录仪,使得该可重复且灵敏的试验具有速度快和成本低的特点。大量健康献血者的Con BA值分布广泛,在我们的189例系列中似乎呈三峰分布。Con BA值清楚地反映了主要Ig类(M、G和A)的水平。对6名初始Con BA值高的个体进行随访证实了这一点。其中4人,观察到Con BA值和IgG浓度平行下降。另外2人,Con BA持续高水平的原因仍无法解释。这些血清的补体成分和活性在正常范围内。由于人聚合γ球蛋白(AHG)参考曲线的波动,结果的表达基于6份正常血清的标准差。鉴于上述结果,这些血清是从Con BA值最低的血清中选择的。基于Con BA和C1q BA可能检测到抗原/抗体比例不同的CIC,对有或无传统类风湿因子(RF)的类风湿性关节炎和慢性活动性B型肝炎患者的血清进行了Con BA和C1q BA分析。可能含有抗原过量的CIC的含RF血清,仅导致最高的C1q BA值和最低的Con BA值。相反,C1q BA-Con BA +血清优先为RF阴性。有人提出,如此检测到的复合物可能具有独特型-抗独特型性质。