[使用75硒标记的同型牛磺胆酸(75Se-HCAT)对各种胆汁酸分泌测量方法的比较研究]

[Comparative studies of various methods of measuring bile acid secretion using 75Se-labelled homotaurocholic acid (75Se-HCAT)].

作者信息

Freundlieb O, Szy D, Balzer K, Strötges M W

出版信息

Nuklearmedizin. 1983 Oct;22(5):258-61.

PMID:6419203
Abstract

The simple determination of whole-body retention of the bile acid analogue 75Se-HCAT provides results which are in agreement with those of the established but more difficult measurement of 24-14C-TCA excretion in the feces. Determining whole-body retention of 75Se-HCAT is not only practicable with a whole-body counter but also, with precision, with the more widely used gamma camera. Therefore, the bile acid retention test may be employed wherever there is a gamma camera available.

摘要

胆汁酸类似物75硒-同型胆酸全身潴留的简单测定结果,与已确立但更复杂的粪便中24-14C-三氯乙酸排泄量测定结果一致。测定75硒-同型胆酸的全身潴留不仅可以通过全身计数器实现,而且使用更广泛的γ相机也能精确测定。因此,只要有γ相机,就可以进行胆汁酸潴留试验。

相似文献

1
[Comparative studies of various methods of measuring bile acid secretion using 75Se-labelled homotaurocholic acid (75Se-HCAT)].[使用75硒标记的同型牛磺胆酸(75Se-HCAT)对各种胆汁酸分泌测量方法的比较研究]
Nuklearmedizin. 1983 Oct;22(5):258-61.
2
Tests for the absorption of 75Se-labelled homocholic acid conjugated with taurine (75Se-HCAT).75硒标记的牛磺酸结合高胆酸(75Se-HCAT)吸收试验。
Eur J Nucl Med. 1985;10(9-10):455-7. doi: 10.1007/BF00256590.
3
Effect of loperamide and delay of bowel motility on bile acid malabsorption caused by late radiation damage and ileal resection.
Eur J Nucl Med. 1991;18(5):346-50. doi: 10.1007/BF02285463.
4
Critical analysis of the accuracy of a combined test (75Se-HCAT and 58Co-B12) of ileal function using a whole-body counter.
Clin Phys Physiol Meas. 1987 May;8(2):159-71. doi: 10.1088/0143-0815/8/2/006.
5
[Function tests of the lower small intestine with 75selenium-labeled homotaurocholic acid in Crohn disease and resections of the small intestine].[用75硒标记的高牛磺胆酸对克罗恩病和小肠切除术患者进行回肠下段功能测试]
Dtsch Med Wochenschr. 1985 Sep 20;110(38):1452-7. doi: 10.1055/s-2008-1069027.
6
[75Se]-selenohomotaurocholic acid degradation by bacterial enzymes in vitro and in vivo. Is it still a specific indicator for active ileal bile acid uptake?细菌酶在体外和体内对[75Se] - 硒代高牛磺胆酸的降解。它仍然是回肠主动摄取胆汁酸的特异性指标吗?
Digestion. 1990;47(2):95-104. doi: 10.1159/000200482.
7
A comparison between the use of a shadow shield whole body counter and an uncollimated gamma camera ain the assessment of the seven-day retention of SeHCAT.在评估SeHCAT七天滞留情况时,对使用阴影屏蔽全身计数器和未准直γ相机的情况进行比较。
Br J Radiol. 1984 Jul;57(679):581-4. doi: 10.1259/0007-1285-57-679-581.
8
Retention of 75Se-homotaurocholic acid measured by a low-background whole-body counter.用低本底全身计数器测量75硒-同型牛磺胆酸的潴留情况。
J Nucl Med Allied Sci. 1983 Oct-Dec;27(4):309-12.
9
Imaging and retention measurements of selenium 75 homocholic acid conjugated with taurine, and the carbon 14 glycochol breath test to document ileal dysfunction due to late radiation damage.硒75同型胆酸与牛磺酸结合物的成像和滞留测量,以及碳14甘氨胆酸呼气试验以记录晚期辐射损伤导致的回肠功能障碍。
Eur J Nucl Med. 1991;18(2):124-8. doi: 10.1007/BF00950758.
10
Measurement of bile acid half-life using [75Se]HCAT in health and intestinal diseases. Comparison with [75Se]HCAT abdominal retention methods.使用[75硒] - 氢胆固醇测定健康及肠道疾病状态下胆汁酸的半衰期。与[75硒] - 氢胆固醇腹部滞留法的比较。
Dig Dis Sci. 1992 Feb;37(2):225-32. doi: 10.1007/BF01308176.