Gutjahr G, Störkel S, Kraus W, Albert G, Thelen M
Rofo. 1984 Sep;141(3):297-303. doi: 10.1055/s-2008-1053136.
The volume of 15 autopsied thyroid glands was determined by fluid displacement and compared with their sonographically obtained stereometric volumes. Maximum variation was 8.6%. Thyroid volumes were measured by ultrasound in 100 volunteers between ages 15 and 36. Total mean value was 19.8 ml. with a mean value of 22.1 ml. in the male group and 17.8 ml. in the female group. 20 volunteers had an additional scintigraphic examination. The thyroid volumes estimated by scintiscanning differed up to 85% with the volume measurements from sonography. Sonography scans were obtained from 6 autopsied thyroid glands and compared with the corresponding tissue slices. Tissue structures were reproduced with great accuracy by ultrasound.
通过液体置换法测定了15个尸检甲状腺的体积,并将其与超声获得的立体测量体积进行比较。最大差异为8.6%。对100名年龄在15至36岁之间的志愿者进行了甲状腺超声体积测量。总体平均值为19.8毫升,男性组平均值为22.1毫升,女性组平均值为17.8毫升。20名志愿者还进行了额外的闪烁扫描检查。闪烁扫描估计的甲状腺体积与超声测量的体积相差高达85%。对6个尸检甲状腺进行了超声扫描,并与相应的组织切片进行比较。超声能够高度精确地再现组织结构。