Rodeau J L, Malan A
J Appl Physiol Respir Environ Exerc Physiol. 1981 Jul;51(1):229-31. doi: 10.1152/jappl.1981.51.1.229.
A simple system based on single-stage gas-stream mixing produces accurate O2-CO2 mixtures suitable for studies on water-breath-ing animals. CO2 fractions as low as 0.05% can be obtained, with an output pressure up to 25 kPa and a full range accuracy of +/- 1%.