一种采用高效液相色谱-电化学检测法同时分析人尿液中游离和硫酸结合型去甲变肾上腺素、变肾上腺素及3-甲氧基酪胺的新方法。

A new method for the simultaneous analysis of free and sulfoconjugated normetanephrine, metanephrine, and 3-methoxytyramine in human urine by HPLC with electrochemical detection.

作者信息

Buu N T, Angers M, Chevalier D, Kuchel O

出版信息

J Lab Clin Med. 1984 Sep;104(3):425-32.

PMID:6470566
Abstract

A sensitive and specific assay for free and sulfoconjugated normetanephrine, metanephrine, and 3-methoxytyramine was achieved by tetraphenylboron complexing and by high-performance liquid chromatography with electrochemical detection. Sulfoconjugated metabolites were hydrolyzed by sulfatase. Complexing the 3-O-methylated catecholamines with tetraphenylboron followed by their extraction in either and reextraction in dilute hydrochloric acid succeeded in partially purifying the sample without the use of a prepacked column. Detection by electrochemical technique additionally eliminates unoxidable components in the urine. The relatively high sensitivity of this method permits measurement of metabolite concentrations as low as 10 ng/ml, allowing for the first time the determination of free 3-O-methylated catecholamines in human urine. Hydrolysis by sulfatase specifically identifies the form of the conjugated metabolite. The mean total (free plus sulfoconjugated) values of normetanephrine, metanephrine, and 3-methoxytyramine obtained from 25 normal volunteers were 214, 102, and 227 micrograms/day, respectively. Values were greatly increased in patients with pheochromocytoma. The degree of sulfoconjugation varied, and each individual metabolite was highest with normetanephrine (86%). This method is sensitive, rapid, simple, and can be easily standardized for clinical investigation of pheochromocytoma.

摘要

通过四苯硼络合以及高效液相色谱-电化学检测,实现了对游离和硫酸结合型去甲变肾上腺素、变肾上腺素及3-甲氧基酪胺的灵敏且特异的检测。硫酸结合型代谢物经硫酸酯酶水解。将3-O-甲基化儿茶酚胺与四苯硼络合,然后用醚萃取并在稀盐酸中再萃取,成功地在不使用预装柱的情况下对样品进行了部分纯化。电化学技术检测还消除了尿液中不可氧化的成分。该方法相对较高的灵敏度使得能够测量低至10 ng/ml的代谢物浓度,首次实现了对人尿中游离3-O-甲基化儿茶酚胺的测定。硫酸酯酶水解可特异性鉴定结合型代谢物的形式。从25名正常志愿者获得的去甲变肾上腺素、变肾上腺素及3-甲氧基酪胺的平均总(游离加硫酸结合型)值分别为214、102和227微克/天。嗜铬细胞瘤患者的值大幅升高。硫酸结合程度各不相同,每种代谢物中去甲变肾上腺素的硫酸结合程度最高(86%)。该方法灵敏、快速、简便,且易于标准化用于嗜铬细胞瘤的临床研究。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验