Stearns S M, Lee P W
Lab Anim Sci. 1984 Aug;34(4):395-6.
A method was developed for obtaining serial blood samples from the tail vein of rats. Seventy microliters of blood were collected at the rate of approximately one sample per minute for the quantitative determination of whole blood clearance of radiolabeled compounds. The technique was rapid, reproducible, and kept stress to the test animals at a minimum.
开发了一种从大鼠尾静脉获取系列血样的方法。以大约每分钟采集一个样本的速率采集70微升血液,用于定量测定放射性标记化合物的全血清除率。该技术快速、可重复,并且将对实验动物的应激降至最低。