Beckenbaugh R D, Ilstrup D M
J Bone Joint Surg Am. 1978 Apr;60(3):306-13.
A review of 333 consecutive Charnley total hip arthroplasties four to seven years after operation showed that twenty-eight patients had died, and three deaths were directly related to the surgery. The survivors had an average improvement of 46.6 points in their evaluation scores to a level of 91.3 points. Four deep infections occurred for which removal of the prosthesis was required. Thirteen hips dislocated postoperatively, and five of them required additional surgery. Three were four sciatic-nerve injuries and all but one resolved. Wear of the acetabular component was evident in seventeen hips, measuring two millimeters in six and one millimeter in eleven. With the marking system used, accurate measurement of wear was not possible. Roentgenographic evidence of loosening of the femoral component was found in 24 per cent of the hips, atributable more often to the quality of cement fixation than to the position of the components (varus-valgus). Varus loosening of two millimeters or more was associated with lower evaluation scores.
对连续333例Charnley全髋关节置换术患者术后4至7年的回顾显示,28例患者死亡,其中3例死亡与手术直接相关。幸存者的评估得分平均提高了46.6分,达到91.3分。发生了4例深部感染,需要取出假体。13例髋关节术后脱位,其中5例需要再次手术。有3例坐骨神经损伤,除1例未恢复外其余均恢复。17例髋关节的髋臼部件出现磨损,6例磨损2毫米,11例磨损1毫米。使用该标记系统无法准确测量磨损情况。24%的髋关节有股骨部件松动的X线证据,这更多是由于骨水泥固定质量而非部件位置(内翻-外翻)所致。内翻松动2毫米或更多与较低的评估得分相关。