Abstract

Horn lenses, manufactured from human toenail donor material were implanted intracorneally in 15 rabbits. The thickness of the lenses ranged 0.08 to 0.2 mm, the diameter from 4.5 to 7 mm. 13 lenses were fenestrated, two were not. Within 6 months, growth of corneal tissue into fenestrations of the lenses occurred but no signs of aseptic necrosis were seen histologically. The boundary layer between stroma and horn lens revealed apposition as well as ingrowth of tissue in electron-microscopic studies. Unguinal tissue may be useful in keratoprosthesis on the basis of its permeability to glucose, lack of foreign body-activity and hydrophilia.

摘要

用人指甲供体材料制成的角质透镜被植入15只兔子的角膜内。透镜的厚度在0.08至0.2毫米之间,直径在4.5至7毫米之间。13个透镜有开窗,2个没有。在6个月内,角膜组织长入透镜的开窗内,但组织学上未见到无菌性坏死的迹象。在电子显微镜研究中,基质与角质透镜之间的边界层显示有组织的并置和长入。腹股沟组织因其对葡萄糖的通透性、缺乏异物活性和亲水性,可能在角膜移植术中有用。