Lanyon L E, Rubin C T
J Biomech. 1984;17(12):897-905. doi: 10.1016/0021-9290(84)90003-4.
Remodelling activity in the avian ulna was assessed under conditions of disuse alone, disuse with a superimposed continuous compressive load, and disuse interrupted by a short daily period of intermittent loading. The ulnar preparation consisted of the 110mm section of the bone shaft between two submetaphyseal osteotomies. Each end of the preparation was transfixed by a stainless steel pin and the shaft either protected from normal functional loading with the pins joined by external fixators, loaded continuously in compression by joining the pins with springs, or loaded intermittently in compression for a single 100s period per day by engaging the pins in an Instron machine. Similar loads (525 N) were used in both static and dynamic cases. The strains engendered were determined by strain gauges, and at their maximum around the bone's midshaft were -0.002. The intermittent load was applied at a frequency of 1 Hz as a ramped square wave, with a rate of change of strain during the ramp of 0.01 s-1. Peak strain at the midshaft of the ulna during wing flapping in the intact bone was recorded from bone bonded strain gauges in vivo as -0.0033 with a maximum rate of change of strain of 0.056 s-1. Examination of bone sections from the midpoint of the preparation after an 8 week period indicated that in both non-loaded and statically loaded bones there was an increase in both endosteal diameter and intra cortical porosity. These changes produced a decrease in cross sectional area which was similar in the two groups (-13%).(ABSTRACT TRUNCATED AT 250 WORDS)
在单独废用、废用叠加持续压缩负荷以及废用期间每天短时间间歇性负荷打断废用的条件下,评估了禽类尺骨的重塑活动。尺骨标本由两个干骺端截骨之间110毫米长的骨干部分组成。标本的两端用不锈钢针固定,骨干要么通过外固定器连接针来防止正常功能负荷,要么通过弹簧连接针进行持续压缩加载,要么每天通过将针与英斯特朗试验机连接进行单次100秒的间歇性压缩加载。在静态和动态情况下使用了相似的负荷(525牛)。产生的应变由应变片测定,在骨干中部周围最大应变值为-0.002。间歇性负荷以1赫兹的频率作为斜坡方波施加,斜坡期间应变变化率为0.01秒-1。完整骨骼在翅膀扇动时尺骨骨干中部的峰值应变,通过体内粘贴在骨上的应变片记录为-0.0033,最大应变变化率为0.056秒-1。8周后对标本中点处的骨切片检查表明,在未加载和静态加载的骨骼中,骨内膜直径和皮质内孔隙率均增加。这些变化导致两组的横截面积均减小(-13%)。(摘要截短至250字)