Wood C, Downing B, McKenzie I, O'Brien B M, Paterson P
Fertil Steril. 1978 Jun;29(6):607-13.
An unsuccessful human fallopian tube transplant is reported. A microsurgical technique is described which initially secured a viable transplant. However, the allograft subsequently died, probably as a result of rejection. Immunosuppression of the patient caused no complications or difficulties, the donor sharing one HL-A haplotype with the patient. The operative procedure, the risks of immunosuppression, and the ethical aspects of the case are discussed in order to present the problems associated with fallopian tube transplantation.