• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Physical fitness of New Zealand army personnel; correlation between field tests and direct laboratory assessments--anaerobic threshold and maximum O2 uptake.

作者信息

O'Donnell C, Smith D A, O'Donnell T V, Stacy R J

出版信息

N Z Med J. 1984 Jul 25;97(760):476-9.

PMID:6591000
Abstract

Performance in two field tests was compared with maximum oxygen uptake (V02max) and anaerobic threshold in 42 male army staff. V02max was measured directly during incremental treadmill exercise. Anaerobic threshold was determined simultaneously from changes in ventilation and gas-exchange. The time to run 2.4 km and the distance covered in 12 minutes were each measured within a week of the laboratory assessments. V02max ranged from 39.8 to 66.0 ml kg-1min-1 with a mean of 50.8 ml kg-1 min-1 (SD 6.2) for the group. Mean anaerobic threshold was 30.7 ml kg-1min-1 (SD 5.5). These values compare favourably with those for other military populations. The time to run 2.4 km averaged 616 s (SD 60) for the group while the mean distance covered in 12 minutes was 2.78 km (SD 0.25). The time for the 2.4 km run showed a significant inverse correlation with both V02max (r = 0.83) and anaerobic threshold (r = 0.81). The linear correlations between 12 min run distance and V02max (r = 0.72) or anaerobic threshold (r = 0.70) were lower. V02max and anaerobic threshold may be justifiably estimated using such field tests.

摘要

相似文献

1
Physical fitness of New Zealand army personnel; correlation between field tests and direct laboratory assessments--anaerobic threshold and maximum O2 uptake.
N Z Med J. 1984 Jul 25;97(760):476-9.
2
Relationships between walk/run performance and cardiorespiratory fitness in adolescents who are overweight.超重青少年的步行/跑步表现与心肺适能之间的关系。
Phys Ther. 2001 Dec;81(12):1889-96.
3
Influence of muscle fibre type and fitness on the oxygen uptake/power output slope during incremental exercise in humans.肌肉纤维类型和体能对人体递增运动期间摄氧量/功率输出斜率的影响。
Exp Physiol. 2000 Jan;85(1):109-16.
4
Determination of the anaerobic threshold by gas exchange: biochemical considerations, methodology and physiological effects.通过气体交换测定无氧阈:生化考量、方法及生理效应
Z Kardiol. 1994;83 Suppl 3:1-12.
5
[Anaerobic threshold as determined by gas metabolic parameters].[通过气体代谢参数确定的无氧阈]
Space Med Med Eng (Beijing). 1998 Oct;11(5):329-32.
6
Determination of lactate threshold by respiratory gas exchange measures and blood lactate levels during incremental load work.在递增负荷运动中通过呼吸气体交换测量和血乳酸水平测定乳酸阈。
J Manipulative Physiol Ther. 1993 Jun;16(5):312-8.
7
Peak oxygen uptake and ventilatory anaerobic threshold in fibromyalgia.纤维肌痛患者的峰值摄氧量和通气无氧阈
J Rheumatol. 2002 Feb;29(2):353-7.
8
Aerobic and anaerobic threshold of Japanese male adults.日本成年男性的有氧和无氧阈值。
J Hum Ergol (Tokyo). 1980 Dec;9(2):183-9.
9
Reproducibility of time at or near VO2max during intermittent treadmill running.间歇性跑步机跑步期间接近或达到最大摄氧量时的时间重复性
Int J Sports Med. 2007 Jan;28(1):40-7. doi: 10.1055/s-2006-923856. Epub 2006 Feb 14.
10
Analysis of performance in orienteering with treadmill tests and physiological field tests using a differential global positioning system.利用跑步机测试和使用差分全球定位系统的生理现场测试对定向越野表现进行分析。
J Sports Sci. 2002 Jul;20(7):529-35. doi: 10.1080/026404102760000035.