AJR Am J Roentgenol. 1983 Mar;140(3):511-5. doi: 10.2214/ajr.140.3.511.
High-frequency real-time sonography has enhanced accuracy in the diagnosis of scrotal abnormalities. Results of 48 scrotal scans of 92 testes are presented. There were 22 testicular lesions, nine seminomas, four embryonal cell carcinomas, one case of metastatic prostatic carcinoma, one benign "keratin cyst," three testicular infarcts, three atrophied testes, and one case of testicular torsion. Hypoechoic tumors and infarcts have a similar appearance. Extratesticular abnormalities included spermatoceles, varicoceles, epididymitis, hydroceles, and a scrotal hematoma. Sonography accurately distinguished between testicular and extratesticular masses in all cases in this series and pathologic correlations were obtained for all testicular masses. Simultaneous real-time contact scanning and palpation facilitated accurate diagnosis.
高频实时超声检查提高了阴囊异常诊断的准确性。本文展示了对92个睾丸进行48次阴囊扫描的结果。其中有22个睾丸病变,包括9个精原细胞瘤、4个胚胎细胞癌、1例转移性前列腺癌、1个良性“角质囊肿”、3个睾丸梗死、3个萎缩睾丸以及1例睾丸扭转。低回声肿瘤和梗死有相似的表现。睾丸外异常包括精液囊肿、精索静脉曲张、附睾炎、鞘膜积液和阴囊血肿。在本系列所有病例中,超声检查都能准确区分睾丸和睾丸外肿块,并且所有睾丸肿块都获得了病理对照。同时进行实时接触扫描和触诊有助于准确诊断。