Multilayer film analysis for glucose in 1-microL samples of plasma.

作者信息

Neeley W E, Zettner A

出版信息

Clin Chem. 1983 Dec;29(12):2103-5.

PMID:6640910
Abstract

With the ultramicroanalytical system described here we can measure glucose in 1 microL of plasma or serum. The sample is placed on a dry, multilayer film element (Eastman Kodak), where a colored spot about 3.5 mm in diameter develops. The reflectance of these spots is measured with a reflectance digital matrix photometer that was conceived, designed, and constructed in our laboratory. The spot is illuminated with monochromatic light and its image is projected by a camera lens onto the photosensitive surface of a linear photodiode array containing 512 individual photodetectors. The photodetector signals are processed by a computer to obtain the reflectance and diameter of the spot. The latter is proportional to sample volume. Because the reflectance of the spot does not depend greatly on sample volume, accurate pipetting is not required. The coefficients of variation of repeatable glucose analyses were, for 400, 3000, and 5120 mg/L, 1.7, 2.3, and 2.8%, respectively. The correlation coefficient (r) between glucose analyses by our method (y) and with the Ektachem 400 (x) was 0.9918; the regression equation was y = 1.07x - 94.3 mg/L.

摘要

相似文献

1
Multilayer film analysis for glucose in 1-microL samples of plasma.
Clin Chem. 1983 Dec;29(12):2103-5.
2
A reflectance photometer with a square photodiode array detector for use on multilayer dry-film slides.
Clin Chem. 1988 Nov;34(11):2367-70.
3
Reflectance digital matrix photometry.反射式数字矩阵光度测定法。
Clin Chem. 1983 Jun;29(6):1038-41.
4
Clinical laboratory evaluation of Ames' Seralyzer Reflectance Photometer for total bilirubin and cholesterol.
Clin Chem. 1983 May;29(5):844-6.
5
Extended clinical trial and evaluation of glucose determination with the Eastman Kodak Ektachem GLU/BUN Analyzer.
Clin Chem. 1981 Jan;27(1):27-34.
6
An instrument for digital matrix photometry.一种用于数字矩阵光度测量的仪器。
Clin Chem. 1981 Oct;27(10):1665-8.
7
Plasma glucose concentrations of whole blood, as determined with a multilayer-film analytical element.
Clin Chem. 1981 Jul;27(7):1287-90.
8
Clinical validation of an automated thin-film reflectance method for measurement of magnesium in serum and urine.一种用于测量血清和尿液中镁含量的自动薄膜反射法的临床验证
Magnesium. 1988;7(2):84-90.
9
Evaluation of a new reflectance photometer for use in home blood glucose monitoring.
Diabetes Care. 1981 Sep-Oct;4(5):547-50. doi: 10.2337/diacare.4.5.547.
10
HemoCue beta-glucose photometer evaluated for use in a neonatal intensive care unit.
Clin Chem. 1993 Nov;39(11 Pt 1):2329-32.