• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

[Study of hemodynamics using a flow-pressure transducer].

作者信息

Matsievskiĭ D D

出版信息

Biull Eksp Biol Med. 1984 Mar;97(3):377-9.

PMID:6704538
Abstract

A method for simultaneous measuring the pressure and blood flow through the vascular wall is described. It is based on the application of a miniature pressure transducer combined with an ultrasonic blood flow transducer. The tests were performed in a Pitotube by means of pulsing flows. The flow-pressure transducer was applied to studying the hemodynamics of the cat thoracic aorta.

摘要

相似文献

1
[Study of hemodynamics using a flow-pressure transducer].
Biull Eksp Biol Med. 1984 Mar;97(3):377-9.
2
Ultrasonic transesophageal measurement of hemodynamic parameters in humans.人体血流动力学参数的超声经食管测量
ISA Trans. 1979;18(1):57-61.
3
Ultraminiature strain gauge transducer for assessing regional intramyocardial pressure.
Med Instrum. 1981 Mar-Apr;15(2):121-4.
4
[Insertion behavior of miniature IBW-79 pressure transducers in the left heart].[微型IBW-79压力传感器在左心的插入行为]
Z Gesamte Inn Med. 1986 Nov 15;41(22):638-40.
5
[Histomorphological findings in the ascending aorta and inferior vena cava following implantation of ultrasonic Doppler flow transducers and pressure transducers in long-term experiments with rabbits and cats].[在兔和猫的长期实验中植入超声多普勒血流传感器和压力传感器后升主动脉和下腔静脉的组织形态学发现]
Anat Anz. 1984;157(5):343-50.
6
Telemetered epidural pressure.遥测硬膜外压力
Biotelemetry. 1975;2(5):257-64.
7
Pressure-flow loops and instantaneous input impedance in the thoracic aorta: another way to assess the effect of aortic bypass graft implantation on myocardial, brain, and subdiaphragmatic perfusion.胸主动脉的压力-流量环和瞬时输入阻抗:评估主动脉旁路移植术对心肌、脑和膈下灌注影响的另一种方法。
J Thorac Cardiovasc Surg. 2003 Mar;125(3):699-710. doi: 10.1067/mtc.2003.104.
8
Zero stability of disposable and reusable pressure transducers.一次性和可重复使用压力传感器的零点稳定性。
Med Instrum. 1987 Apr;21(2):87-91.
9
Effect of an experimental stenosis in the porcine descending thoracic aorta.猪胸降主动脉实验性狭窄的影响。
Artif Organs. 2004 Nov;28(11):987-92. doi: 10.1111/j.1525-1594.2004.00010.x.
10
A comparison of sitting pressures on wheelchair cushions as measured by air cell transducers and miniature electronic transducers.通过气囊传感器和微型电子传感器测量的轮椅坐垫坐姿压力比较。
Bull Prosthet Res. 1980 Spring;10-33:5-8.