Lang C, Zeller C, Scherrer M
Schweiz Med Wochenschr. 1984 Mar 3;114(9):292-6.
In 130 healthy young men and women aged 15 to 20 years, all non-smokers, volume flow curves were recorded during forced expiratory vital capacity measurements. The forced vital capacity (FVC), the forced expiratory volume of 1 sec (FEV1) and the mid-expiratory flow rate (MEF50) were evaluated in order to establish new standard values for normal people in this particular age group. FVC is strongly height and sex dependent. Our new normal values are in good agreement with those of the literature. Our FVC values, however, are in general slightly higher than those of previous authors. MEF50 turns out to be sex independent but height dependent, but not as much as FVC. Our new normal values for MEF50 are in good agreement with those of Knudson et al., though slightly lower. The FEV1/FVC quotient was found to decrease significantly with height from 0.9 to 0.8. This decrease may be due to the increase in lung volume with growth. It could also be due to lung damage caused by atmospheric air pollution in young adults who are still growing.
在130名年龄在15至20岁的健康青年男女(均不吸烟)中,于用力呼气肺活量测量期间记录了容积流量曲线。评估了用力肺活量(FVC)、1秒用力呼气量(FEV1)和呼气中期流速(MEF50),以便为该特定年龄组的正常人建立新的标准值。FVC强烈依赖身高和性别。我们的新正常值与文献中的值高度一致。然而,我们的FVC值总体上略高于先前作者报道的值。结果表明,MEF50与性别无关,但与身高有关,不过不像FVC那样依赖身高。我们的MEF50新正常值与Knudson等人的结果高度一致,尽管略低。发现FEV1/FVC商数随身高显著下降,从0.9降至0.8。这种下降可能是由于随着生长肺容积增加所致。也可能是由于仍在生长的年轻成年人因大气空气污染导致的肺损伤。