Everett R L
J Assoc Off Anal Chem. 1984 Mar-Apr;67(2):225-7.
A reverse phase liquid chromatographic method was developed for determining methocarbamol in injection and tablet dosage forms. The injections require dilution only; the tablets require a filtration step before introduction into the chromatograph. Response for methocarbamol was linear over the range 0-18 micrograms, using an ultraviolet detector at 274 nm. Recoveries by the author ranged from 96.1 to 101.9% for authentic injection formulations and 98.0 to 101.0% for authentic tablet formulations. A collaborative study of the method by 6 laboratories resulted in standard deviations of 1.70 and 2.22 for injection and tablet dosage forms, respectively. The method has been adopted official first action.
已开发出一种反相液相色谱法,用于测定注射剂和片剂剂型中甲氯芬那酯的含量。注射剂仅需稀释;片剂在进样前需经过过滤步骤。使用274nm紫外检测器时,甲氯芬那酯在0-18微克范围内响应呈线性。作者对正品注射剂的回收率在96.1%至101.9%之间,对正品片剂的回收率在98.0%至101.0%之间。6个实验室对该方法进行的协作研究得出,注射剂和片剂剂型的标准偏差分别为1.70和2.22。该方法已被官方首次采用。