Abstract

To find a commercially available DTPA preparation that could be used for the measurement of glomerular filtration rate (GFR), the plasma clearances of four different Tc-99m(Sn)DTPA preparations were compared with that of Cr-51 EDTA using a single-injection technique. One preparation yielded results identical to those obtained with Cr-51 EDTA, whereas the others underestimated the GFR to a varying degree. It is concluded that Tc-99m DTPA can be used to estimate the GFR, but that the accuracy will depend on the commercial source.

摘要

为了找到一种可用于测量肾小球滤过率(GFR)的市售二乙三胺五乙酸(DTPA)制剂,采用单次注射技术,比较了四种不同的锝-99m(锡)DTPA制剂与铬-51依地酸(EDTA)的血浆清除率。一种制剂得到的结果与铬-51 EDTA得到的结果相同,而其他制剂则不同程度地低估了GFR。结论是,锝-99m DTPA可用于估计GFR,但准确性将取决于商业来源。