一种无二氧化碳吸收功能的循环系统。

A circle system without carbon dioxide absorption.

作者信息

Ladegaard-Pedersen H J

出版信息

Acta Anaesthesiol Scand. 1978;22(3):281-6. doi: 10.1111/j.1399-6576.1978.tb01302.x.

Abstract

An anaesthetic circle system without a carbon dioxide absorber is described. The efficiency of the circle, i.e., the fraction of alveolar gas in the outflow from the circle, was measured in 15 patients during halothane anaesthesia or neurolept analgesia. The fraction ranged from 0.88 to 0.95 (mean 0.91), while the ratio between the alveolar ventilation and the fresh gas inflow ranged from 0.97 to 1.71. The efficiency was not correlated to this ratio. There was no need for hyperventilation if the fresh gas inflow was 10% higher than the alveolar ventilation required to maintain normal PaCO2. The circle was used in 50 patients manually ventilated by nurse anaesthetists. Mean fresh gas inflow was 60 ml/kg. Mean PaCO2 was 5.47 kPa (41 mmHg). In a similar group of 50 other patients, in which the standard circle used in the department was employed, the mean PaCO2 was 4.80 kPa (36 mmHg). The frequency of hypercapnia was equal in the two groups, but hypocapnia was not seen when the circle without absorber was used.

摘要

本文描述了一种无二氧化碳吸收器的麻醉环路系统。在15例接受氟烷麻醉或神经安定镇痛的患者中,测量了该环路的效率,即环路流出气体中肺泡气的比例。该比例范围为0.88至0.95(平均0.91),而肺泡通气与新鲜气体流入量之比范围为0.97至1.71。效率与该比例无关。如果新鲜气体流入量比维持正常动脉血二氧化碳分压(PaCO2)所需的肺泡通气量高10%,则无需过度通气。该环路系统由麻醉护士手动通气用于50例患者。平均新鲜气体流入量为60 ml/kg。平均PaCO2为5.47 kPa(41 mmHg)。在另一组50例使用科室标准环路系统的类似患者中,平均PaCO2为4.80 kPa(36 mmHg)。两组高碳酸血症的发生率相同,但使用无吸收器环路时未出现低碳酸血症。

相似文献

1
A circle system without carbon dioxide absorption.一种无二氧化碳吸收功能的循环系统。
Acta Anaesthesiol Scand. 1978;22(3):281-6. doi: 10.1111/j.1399-6576.1978.tb01302.x.
3
Normocapnic ventilation using the circle system.使用环路系统进行正常碳酸血症通气。
Can Anaesth Soc J. 1976 Nov;23(6):657-66. doi: 10.1007/BF03006749.