Determination of cardiac output based on breath-holding.

作者信息

Hoffstein V, Rebuck A S

出版信息

Crit Care Med. 1980 Nov;8(11):671-4. doi: 10.1097/00003246-198011000-00017.

DOI:10.1097/00003246-198011000-00017
PMID:6775875
Abstract

A breath-holding method for determination of cardiac output is described. It is based on the indirect Fick principle applied to carbon dioxide. Mixed venous PCO2 (PvCO2) is measured noninvasively using a CO2 breath-holding technique and PaCO2 is obtained by arterial puncture. Partial pressures are converted into contents using each patient's CO2 dissociation curve, taking into account temperature, hemoglobin, arterial and venous pH. The authors have applied this method to the determination of cardiac output in 20 patients, in whom cardiac output was also measured invasively using either direct Fick or thermodilution method. Mean cardiac output determined using the breath-holding method was 5.48 +/- 2.95 (SD) L/min, compared to 5.54 +/- 2.88 L/min as determined by the direct Fick or thermodilution method. Good correlation was found between the invasive and breath-holding method (r = 0.97, p < 0.001). The authors conclude that cardiac output at rest may be estimated with considerable accuracy from the measurements of PaCO2, CO2 production and the breath-holding mixed venous PCO2 without right-sided cardiac catheterization.

摘要

相似文献

1
Determination of cardiac output based on breath-holding.
Crit Care Med. 1980 Nov;8(11):671-4. doi: 10.1097/00003246-198011000-00017.
2
Accuracy of an indirect carbon dioxide Fick method in determination of the cardiac output in critically ill mechanically ventilated patients.
Intensive Care Med. 1988;14(2):131-5. doi: 10.1007/BF00257466.
3
Measurement of cardiac output by carbon dioxide rebreathing methods.通过二氧化碳重呼吸法测量心输出量。
Clin Chest Med. 1989 Jun;10(2):255-64.
4
Carbon dioxide rebreathing method of cardiac output measurement during acute respiratory failure in patients with chronic obstructive pulmonary disease.慢性阻塞性肺疾病患者急性呼吸衰竭时心输出量测量的二氧化碳重吸入法
Crit Care Med. 1994 Jan;22(1):81-5. doi: 10.1097/00003246-199401000-00017.
5
The non-invasive determination of cardiac output in children: a three-breath technique.
Anesthesiology. 1988 Aug;69(2):223-6. doi: 10.1097/00000542-198808000-00011.
6
Determination of cardiac output at rest and during exercise by carbon dioxide rebreathing method in obstructive airway disease.
Am Rev Respir Dis. 1985 Jan;131(1):73-8. doi: 10.1164/arrd.1985.131.1.73.
7
Real-time gas-exchange measurement of oxygen consumption in neonates and infants after cardiac surgery.心脏手术后新生儿和婴儿氧气消耗的实时气体交换测量
Crit Care Med. 1993 Sep;21(9):1369-75. doi: 10.1097/00003246-199309000-00022.
8
Comparison of exercise cardiac output by the Fick principle using oxygen and carbon dioxide.运用氧和二氧化碳通过菲克原理对运动心输出量进行比较。
Chest. 2000 Sep;118(3):631-40. doi: 10.1378/chest.118.3.631.
9
Oxygen Fick and modified carbon dioxide Fick cardiac outputs.氧耗量菲克法和改良二氧化碳菲克法心输出量。
Crit Care Med. 1994 Jan;22(1):86-95. doi: 10.1097/00003246-199401000-00018.
10
Non-invasive measurement of cardiac output by a carbon dioxide rebreathing method at rest and during exercise.通过二氧化碳重呼吸法在静息和运动期间无创测量心输出量。
Eur Heart J. 1994 Mar;15(3):361-8. doi: 10.1093/oxfordjournals.eurheartj.a060504.

引用本文的文献

1
Pulmonary blood flow (cardiac output) and the effective lung volume determined from a short breath hold using the differential Fick method.肺血流量(心输出量)和使用差分菲克法通过短暂屏气测定的有效肺容积。
J Clin Monit Comput. 2002 Jul;17(5):313-21. doi: 10.1023/a:1021232624767.