Fleenor W A, Stott G H
J Dairy Sci. 1981 May;64(5):740-7. doi: 10.3168/jds.S0022-0302(81)82642-2.
Relative accuracy of the single radial immunodiffusion technique to measure immunoglobulin concentrations of colostral preparations (whey, whole, or fat-free) has been assessed. Fresh colostrum samples were analyzed for major constituents. Gammaglobulin as a standard was compared to total immunoglobulin concentration derived from single radial immunodiffusion analysis of colostral preparations with no differences except between standard and whey. Differences were in part from either enhancement or interference of immunoglobulin diffusion by colostral constituents. Removal of casein and fat during whey preparations caused a concentrating effect upon immunoglobulin constituents resulting in exaggerated precipitin rings. Whey has produced unreliable results: therefore, whole colostrum is recommended for single radial immunodiffusion analysis.
已评估单扩散免疫比浊技术用于测量初乳制剂(乳清、全乳或脱脂乳)免疫球蛋白浓度的相对准确性。对新鲜初乳样本的主要成分进行了分析。将γ球蛋白作为标准品,与通过单扩散免疫比浊分析初乳制剂得出的总免疫球蛋白浓度进行比较,除了标准品与乳清之间存在差异外,其他并无差异。这些差异部分源于初乳成分对免疫球蛋白扩散的增强或干扰。在制备乳清的过程中去除酪蛋白和脂肪,会对免疫球蛋白成分产生浓缩作用,导致沉淀环过大。乳清产生的结果不可靠:因此,建议使用全初乳进行单扩散免疫比浊分析。