Suppr超能文献

比较浊度免疫测定法和折射仪比浊法与放射免疫扩散法评估牛肉牛初乳免疫球蛋白浓度。

Comparison of turbidometric immunoassay and brix refractometry to radial immunodiffusion for assessment of colostral immunoglobulin concentration in beef cattle.

机构信息

Veterinary Clinical Sciences, Iowa State University, Ames, Iowa 50011, USA.

Veterinary Diagnostic & Production Animal Medicine, Iowa State University, Ames, Iowa 50011, USA.

出版信息

J Vet Intern Med. 2023 Sep-Oct;37(5):1934-1943. doi: 10.1111/jvim.16833. Epub 2023 Aug 19.

Abstract

BACKGROUND

Colostral immunoglobulin G (IgG) concentration is critical to the attainment of adequate transfer of passive immunity in cattle, however, studies comparing available tools for measurement of colostral IgG concentration in beef cattle are limited.

OBJECTIVES

To report the agreement between 3 commercially available tests for evaluating IgG concentration in beef colostrum.

ANIMALS

Two hundred six beef-breed cows hospitalized for calving management or dystocia.

METHODS

Retrospective study to assess IgG of whole colostrum measured stall-side via turbidimetric immunoassay (TI) and brix refractometry (BRIX), compared to fat separated (FS) analysis via single radial-immunodiffusion (RID; reference standard), TI-FS and BRIX-FS. Test performance was assessed using Passing Bablock regression, Bland-Altman analysis, and area under the curve to determine optimal thresholds.

RESULTS

Correlation between RID and TI-FS, BRIX-FS, or BRIX was similar (Spearman's ρ = 0.717, 0.715, 0.716, respectively) but correlation for TI was poor (ρ = 0.586). Regression analysis identified a substantial constant (-214.75 [CI: -272.03 to -178.07]) and proportional (13.24 [CI: 11.81-15.37]) bias between the RID and TI-FS which was similar for TI. TI-FS concentrations of 28.47, 38.75, and 50.62 g/L, BRIX-FS of ≤21.9%, ≤24.0%, and ≤27.4%, and BRIX of ≤21.3%, ≤23.8%, and ≤26.4% indicated IgG concentrations <50, <100, and <150 g/L, respectively; appropriate cutoffs for TI could not be generated.

CONCLUSIONS AND CLINICAL IMPORTANCE

Both TI and TI-FS demonstrated a large constant and proportional bias compared to RID; BRIX and BRIX-FS were well correlated with RID and remain a reliable method for estimation of colostral IgG concentration in beef cattle.

摘要

背景

初乳免疫球蛋白 G(IgG)浓度对牛获得充分的被动免疫转移至关重要,但比较评估牛肉牛初乳 IgG 浓度的现有工具的研究有限。

目的

报告 3 种商业上可用于评估牛肉初乳 IgG 浓度的检测方法的一致性。

动物

206 头因产犊管理或难产住院的肉牛品种奶牛。

方法

回顾性研究评估通过比浊免疫测定法(TI)和折射计(BRIX)在牛舍现场测量的全初乳 IgG,与通过单扩免疫扩散法(RID;参考标准)分离脂肪后的分析进行比较,TI-FS 和 BRIX-FS。使用 Passing Bablock 回归、Bland-Altman 分析和曲线下面积评估检测性能,以确定最佳阈值。

结果

RID 与 TI-FS、BRIX-FS 或 BRIX 的相关性相似(Spearman ρ分别为 0.717、0.715、0.716),但 TI 的相关性较差(ρ=0.586)。回归分析确定 RID 和 TI-FS 之间存在较大的恒定偏差(-214.75 [CI:-272.03 至-178.07])和比例偏差(13.24 [CI:11.81-15.37]),这与 TI 相似。28.47、38.75 和 50.62 g/L 的 TI-FS 浓度、BRIX-FS 的≤21.9%、≤24.0%和≤27.4%以及 BRIX 的≤21.3%、≤23.8%和≤26.4%分别表示 IgG 浓度<50、<100 和<150 g/L;无法为 TI 生成适当的截断值。

结论和临床意义

TI 和 TI-FS 与 RID 相比均显示出较大的恒定和比例偏差;BRIX 和 BRIX-FS 与 RID 高度相关,仍是评估牛肉牛初乳 IgG 浓度的可靠方法。