Comparison of two methods for detecting microbial contamination in intravenous fluids.

作者信息

Posey L M, Nutt R E, Thomson P D

出版信息

Am J Hosp Pharm. 1981 May;38(5):659-62.

PMID:6792910
Abstract

An aliquot sampling method and a qualitative membrane filltration method of microbial detection in intravenous infusion solutions were compared. One-liter plastic bags of total parenteral nutrition solutions were contaminated at approximately 1000, 100, 10, and 1 organisms per liter using clinically isolated strains of Escheichia coli, Pseudomonas aeruginosa, Staphylococcus epidermidis, and Candida albicans. Ten-milliliter aliquots of the solutions were injected into blood culture bottles to test the aliquot method. All remaining fluid was filtered through the Addi-Chek system to test the filtration method. Samples were incubated at 30 degrees C for 10 days and inspected daily for turbidity. The aliquot sampling method consistently detected each of the four organisms at levels of 100 organisms/liter and above. The membrane filtration method consistently detected all levels of contamination (as few as four organisms/liter). The aliquot sampling method is inexpensive and easy to use but may fail to detect some contaminated solutions. The qualitative membrane filtration system will detect all levels of contamination but is more costly in both time and money, and its reliability has not been assessed objectively.

摘要

相似文献

1
Comparison of two methods for detecting microbial contamination in intravenous fluids.
Am J Hosp Pharm. 1981 May;38(5):659-62.
2
Evaluation of three methods for detecting low-level bacterial contamination in intravenous solutions.三种检测静脉输液中低水平细菌污染方法的评估
Am J Hosp Pharm. 1982 Aug;39(8):1302-5.
3
Evaluation of a device for monitoring sterility of injectable fluids.
Am J Hosp Pharm. 1981 Aug;38(8):1148-50.
4
Evaluation of three methods for detecting bacterial contamination in intravenous solutions.三种检测静脉输液中细菌污染方法的评估
Am J Hosp Pharm. 1982 Aug;39(8):1299-302.
5
Evaluation of two sterility testing methods for intravenous admixtures.静脉药物混合液两种无菌检测方法的评估
Hosp Pharm. 1980 Jun;15(6):305-10.
6
Microbiologic quality assurance for intravenous admixtures in a small hospital.一家小型医院静脉药物混合制剂的微生物质量保证
Am J Hosp Pharm. 1982 May;39(5):832-5.
7
Growth of bacteria and fungi in parenteral nutrition solutions containing albumin.含白蛋白的肠外营养溶液中细菌和真菌的生长
Am J Hosp Pharm. 1981 Dec;38(12):1907-10.
8
Amino acid stability and microbial growth in total parenteral nutrient solutions.
Am J Hosp Pharm. 1985 Dec;42(12):2688-91.
9
Sterility testing of home and inpatient parenteral nutrition solutions.
JPEN J Parenter Enteral Nutr. 1988 Jan-Feb;12(1):25-8. doi: 10.1177/014860718801200125.
10
Microbial growth patterns in intravenous fat emulsions.静脉脂肪乳剂中的微生物生长模式。
Am J Hosp Pharm. 1983 Oct;40(10):1650-3.

引用本文的文献

1
Comparison of the standard pour plate procedure and the ATP and Limulus amebocyte lysate procedures for the detection of microbial contamination in intravenous fluids.用于检测静脉输液中微生物污染的标准倾注平板法、ATP法和鲎试剂法的比较
J Clin Microbiol. 1986 Mar;23(3):465-8. doi: 10.1128/jcm.23.3.465-468.1986.