Corrosion of copper in utero.

作者信息

Kosonen A

出版信息

Fertil Steril. 1978 Jul;30(1):59-65. doi: 10.1016/s0015-0282(16)43397-2.

DOI:10.1016/s0015-0282(16)43397-2
PMID:680184
Abstract

The influence of corrosion on the copper wire in the Copper T-200 intrauterine device (IUD) was studied in devices which had been in utero for 3 to 52 months. This was done mainly by examining cross-sections of the wires under a light microscope. Corrosion was normally localized to narrow areas and led to breakage and fragmentation of the copper wire. Neither deposits on the wire nor corrosion products prevented the dissolution of the copper. The progress of the corrosion over a given time was determined by comparing the depth of corrosion with the original dimension of the wire. The lifetime of the IUD was evaluated on the basis of the progress of corrosion, the calculated copper release, and the number of cases of wire breakage. It was found that the Copper T-200 could be left in place for up to 45 months.

摘要

相似文献

1
Corrosion of copper in utero.
Fertil Steril. 1978 Jul;30(1):59-65. doi: 10.1016/s0015-0282(16)43397-2.
2
Degradation of the copper-releasing intrauterine contraceptive device and its significance.含铜宫内节育器的降解及其意义。
Br J Obstet Gynaecol. 1984 Feb;91(2):172-81. doi: 10.1111/j.1471-0528.1984.tb05903.x.
3
Corrosion of filamentous intra-uterine copper. The MLCu250 and the MLCu375.
Contraception. 1983 Jan;27(1):85-93. doi: 10.1016/0010-7824(83)90059-8.
4
Corrosion of a new copper-gold or copper-platinum intrauterine device.一种新型铜金或铜铂宫内节育器的腐蚀
J Biomed Mater Res. 1982 Nov;16(6):785-98. doi: 10.1002/jbm.820160605.
5
Electrochemical effects of metals on IUDs.金属对宫内节育器的电化学效应。
Int J Fertil. 1977;22(3):155-161.
6
The multisleeved copper T model TCu220C: effect of long-term use on corrosion and dissolution of copper.多套管铜T型节育器TCu220C:长期使用对铜腐蚀和溶解的影响
Contraception. 1987 Feb;35(2):163-70. doi: 10.1016/s0010-7824(87)80007-0.
7
Corrosion and weight loss from copper wire in the Fincoid IUD in utero.
Contracept Deliv Syst. 1984;5(2):105-8.
8
A copper-based intrauterine device with gold or platinum core: in vitro and in vivo studies.
Contraception. 1981 Dec;24(6):657-71. doi: 10.1016/0010-7824(81)90017-2.
9
[Release of copper by the Nova-T and ML Cu 250 short intrauterine devices].[Nova-T和ML Cu 250型短效宫内节育器的铜释放情况]
Arch Gynecol Obstet. 1989;245(1-4):1013-5. doi: 10.1007/BF02417661.
10
Release behavior of cupric ions for TCu380A and TCu220C IUDs.TCu380A和TCu220C宫内节育器中铜离子的释放行为。
Biomed Mater. 2008 Dec;3(4):044114. doi: 10.1088/1748-6041/3/4/044114. Epub 2008 Nov 25.

引用本文的文献

1
Decreased endometrial HOXA10 expression associated with use of the copper intrauterine device.子宫内膜 HOXA10 表达降低与使用铜宫内节育器有关。
Fertil Steril. 2009 Dec;92(6):1820-4. doi: 10.1016/j.fertnstert.2008.08.134. Epub 2008 Oct 18.
2
Characterization of copper corrosion products originated in simulated uterine fluids and on packaged intrauterine devices.模拟子宫液及包装宫内节育器上产生的铜腐蚀产物的表征
J Mater Sci Mater Med. 2001 May;12(5):391-7. doi: 10.1023/a:1011288701499.