Fleetwood L, Shu-rong Z, Eneroth P, Landgren B M
Contraception. 1983 Apr;27(4):329-38. doi: 10.1016/s0010-7824(83)80013-4.
Total urinary estrogens (TUE) in morning urine samples delivered during seven days around midcycle from 14 normally menstruating women were analyzed and the results were compared with those obtained by radioimmunoassay of serum estradiol-17 beta (E2) and LH. The Spinnbarkeit of the cervical mucus was also determined daily and ovulation was confirmed by RIA of serum progesterone. Significant correlations (p less than 0.01) between day of peak levels of serum E2 and the day with the highest TUE value were obtained. Peak values for Spinnbarkeit, estradiol, TUE and LH were on the average obtained on cycle day 13.1 (10-17), 13.3 (10-16), 13.9 (11-18) and 14.1 (11-17), respectively, and the mean cycle length was 27.9 (24-32) days. The difference in mean peak day for estradiol and TUE, estradiol and Spinnbarkeit, estradiol and LH was significant in each comparison (p less than 0.01). Assays of TUE in morning samples as compared to analysis of TUE in 24 h urine portions were compared during 48 h in 10 women. The day with the highest TUE excretion was found to be the same in 7 women irrespective of the type of urinary sample analyzed. Analysis of urinary creatinine did not improve the TUE results. Levels of TUE in normally cycling females (n = 14); in women taking contraceptive steroids (n = 10), in menopausal women (n = 10) and in normal men (n = 10) agreed with those previously reported. It is concluded that the TUE determination by RIA may be helpful as a rapid method for everyday clinical use.
对14名月经正常的女性在月经周期中期前后7天内每天早晨送检的尿样中的总尿雌激素(TUE)进行了分析,并将结果与通过放射免疫分析法测定血清雌二醇-17β(E2)和促黄体生成素(LH)所得结果进行了比较。每天还测定宫颈黏液的拉丝度,并通过血清孕酮的放射免疫分析法确认排卵。血清E2峰值水平出现的日期与TUE值最高的日期之间存在显著相关性(p<0.01)。拉丝度、雌二醇、TUE和LH的峰值平均分别出现在月经周期的第13.1天(10 - 17天)、13.3天(10 - 16天)、13.9天(11 - 18天)和14.1天(11 - 17天),平均月经周期长度为27.9天(24 - 32天)。雌二醇与TUE、雌二醇与拉丝度、雌二醇与LH的平均峰值日差异在每次比较中均具有显著性(p<0.01)。在10名女性中,对48小时内早晨尿样中的TUE测定结果与24小时尿样部分中的TUE分析结果进行了比较。发现7名女性无论分析的尿样类型如何,TUE排泄量最高的日期相同。尿肌酐分析并未改善TUE结果。正常月经周期女性(n = 14)、服用避孕甾体激素的女性(n = 10)、绝经后女性(n = 10)和正常男性(n = 10)的TUE水平与先前报道的一致。结论是,放射免疫分析法测定TUE作为一种日常临床快速方法可能会有帮助。