Suppr超能文献

Comparative quality control of 99mTc-Pyrophosphate and 99mTc-diphosphonate radiopharmaceuticals.

作者信息

Jovanović V, Maksin T, Rastovac M, Bzenić J

出版信息

Eur J Nucl Med. 1983;8(4):179-82. doi: 10.1007/BF00252891.

Abstract

The results of analysis of 99mTc-Pyrophosphate (99mPyP), taken as a representative of the group of compounds having an organic P-O-P bond, and of the three diphosphonate compounds: methylene diphosphonate (MDP), 2,3-dicarboxy propane diphosphonate (DPD) and ethane-1-hydroxy-1, 1-diphosphonate (EHDP), which differ in their chemical structure, are shown. Also, some physicochemical parameters such as chloroform-water apparent partition coefficient, the osmotic pressure and pH values in final preparations were studied. The radiochemical purity of these radiopharmaceuticals was determined by the two methods: Sephadex chromatography for separation of 99mTc-hydrolysate and TLC on silica gel with 85% methanol for the determination of free 99mTcO-4. The yield of labelling for both methods was over 90%. Also, pharmacokinetic parameters such as binding to the plasma proteins and to erythrocytes were determined. 99mTc-PyP binding to plasma proteins was higher than the binding of diphosphonate compounds. The quantitative distribution of preparations was determined in experimental animals.

摘要

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验