Energy and angular dependence of x-ray absorption and its effect on radiographic response in screen--film systems.

作者信息

Chan H P, Doi K

出版信息

Phys Med Biol. 1983 May;28(5):565-79. doi: 10.1088/0031-9155/28/5/009.

DOI:10.1088/0031-9155/28/5/009
PMID:6867113
Abstract

The relationship between the film density and the x-ray energy absorbed in the screens, and the effect of the components of a screen--film system on x-ray absorption in the screen phosphor has been studied. It is concluded that, to a good approximation, the total absorbed x-ray energy can be calculated ignoring components other than the phosphor, and that the absorbed energy is related to the film density through the characteristic curve of the film. This simple relationship provides a basis for the theoretical prediction of the radiographic performance of an imaging system. Analytical expressions have been derived for the energy absorbed in model screens containing one or two high-atomic-number elements. For incident energies above the K-edge of the high-Z elements, the contribution of the K x-rays to energy absorption was included by use of a K-reabsorption factor. This factor was determined for eight screen pairs as a function of incident photon energy and incident angle.

摘要

相似文献

1
Energy and angular dependence of x-ray absorption and its effect on radiographic response in screen--film systems.
Phys Med Biol. 1983 May;28(5):565-79. doi: 10.1088/0031-9155/28/5/009.
2
Wiener spectral effects of spatial correlation between the sites of characteristic x-ray emission and reabsorption in radiographic screen-film systems.
Phys Med Biol. 1983 May;28(5):547-64. doi: 10.1088/0031-9155/28/5/008.
3
Radiographic mottle: a comprehensive theory.射线照相斑纹:一种综合理论。
Med Phys. 1982 Sep-Oct;9(5):656-67. doi: 10.1118/1.595126.
4
Studies of x-ray energy absorption and quantum noise properties of x-ray screens by use of Monte Carlo simulation.
Med Phys. 1984 Jan-Feb;11(1):37-46. doi: 10.1118/1.595474.
5
Absolute speeds of screen-film systems and their absorbed-energy constants.
Radiology. 1984 Apr;151(1):229-36. doi: 10.1148/radiology.151.1.6701320.
6
The energy-dependent behavior of noise Wiener spectra in their low-frequency limits: comparison with simple theory.
Radiology. 1982 Aug;144(3):619-22. doi: 10.1148/radiology.144.3.7100480.
7
Energy absorbed in calcium tungstate x-ray screens.钨酸钙X射线屏中吸收的能量。
Med Phys. 1977 May-Jun;4(3):239-43. doi: 10.1118/1.594373.
8
[Light production from intensifying screens (theoretical and experimental aspects)].[增感屏的发光(理论与实验方面)]
Radiol Med. 1982 Jul-Aug;68(7-8):571-80.
9
[Dependence of the sensitivity of combined intensifying film-screens on the voltage in X-ray tubes].
Med Tekh. 1984 Jul-Aug(4):14-9.
10
Dependence of radiographic sensitivity of CR imaging plate on X-ray tube voltage.计算机X线摄影成像板的X线摄影灵敏度对X射线管电压的依赖性。
Radiol Phys Technol. 2008 Jan;1(1):100-5. doi: 10.1007/s12194-007-0015-9. Epub 2007 Dec 11.

引用本文的文献

1
Software Article: A generalized cascaded linear system model implementation for x-ray detectors.软件文章:一种用于X射线探测器的广义级联线性系统模型实现
Med Phys. 2025 Sep;52(9):e18079. doi: 10.1002/mp.18079.
2
Modeling and evaluation of a high-resolution CMOS detector for cone-beam CT of the extremities.用于四肢锥束 CT 的高分辨率 CMOS 探测器的建模与评估。
Med Phys. 2018 Jan;45(1):114-130. doi: 10.1002/mp.12654. Epub 2017 Nov 27.
3
A theoretical and experimental evaluation of the microangiographic fluoroscope: A high-resolution region-of-interest x-ray imager.
理论和实验评估微血管荧光透视仪:高分辨率感兴趣区域 X 射线成像仪。
Med Phys. 2011 Jul;38(7):4112-26. doi: 10.1118/1.3599751.
4
Progress in electron-multiplying CCD (EMCCD) based, high-resolution, high-sensitivity x-ray detector for fluoroscopy and radiography.基于电子倍增电荷耦合器件(EMCCD)的高分辨率、高灵敏度X射线探测器在荧光透视和射线照相方面的进展。
Proc SPIE Int Soc Opt Eng. 2007;6510(1):65101C. doi: 10.1117/12.713140.
5
Modeling the performance characteristics of computed radiography (CR) systems.计算机放射成像(CR)系统性能特征建模。
IEEE Trans Med Imaging. 2010 Mar;29(3):790-806. doi: 10.1109/TMI.2009.2036995.
6
Solid-state fluoroscopic imager for high-resolution angiography: parallel-cascaded linear systems analysis.用于高分辨率血管造影的固态荧光成像仪:并行级联线性系统分析
Med Phys. 2004 May;31(5):1258-68. doi: 10.1118/1.1689014.