Hadden W A, Reschauer R, Seggl W
Injury. 1983 Jul;15(1):44-52. doi: 10.1016/0020-1383(83)90162-6.
A series of 111 forearm fractures in 108 individuals involving 177 individual bones, and treated by AO plating is reported. There were 18 different surgeons. Open fractures occurred in 24 per cent of limbs. Reviews at a mean of 3 years after the accident showed 97 per cent of bones to be solidly united, and satisfactory function to be achieved in 80 per cent of limbs. Deep infection occurred 6 times, and non-union in 7 bones. Cross-union developed in 6 patients, all of whom had sustained head injuries. Seven patients sustained operative nerve injuries. It is felt that the implant of choice at the moment is the small fragment Dynamic Compression Plate (DCP).
报告了108例患者的111处前臂骨折,共涉及177块骨头,均采用AO钢板治疗。有18位不同的外科医生参与。24%的肢体发生开放性骨折。事故后平均3年的复查显示,97%的骨头牢固愈合,80%的肢体功能良好。发生深部感染6次,7块骨头出现骨不连。6例患者出现交叉愈合,均有头部受伤史。7例患者发生手术相关神经损伤。目前认为,首选的植入物是小型动力加压钢板(DCP)。