Abstract

The performance of clinical chemistry laboratories in New Zealand in the assays of oestriol and creatinine in pregnancy urine has been investigated. The quality of oestriol determinations in general was poor. Only seven of 20 laboratories achieved an inter-assay precision of better than 12 percent consistently through the range of oestriol levels represented by three control urines. The precision of laboratories in assaying urinary creatinine was, however, of a higher standard. Only three of 18 laboratories had precision values that could be regarded overall as unsatisfactory.

摘要

对新西兰临床化学实验室检测妊娠尿液中雌三醇和肌酐的表现进行了调查。总体而言,雌三醇测定的质量较差。在20个实验室中,只有7个实验室在由三种对照尿液所代表的雌三醇水平范围内,始终保持批间精密度优于12%。然而,各实验室检测尿肌酐的精密度则达到了更高的标准。18个实验室中只有3个实验室的精密度值总体上可被视为不令人满意。