Suppr超能文献

表面置换全髋关节置换失败的放射学表现

Radiology of failed surface-replacement total-hip arthroplasty.

作者信息

Bassett L W, Gold R H, Hedley A K

出版信息

AJR Am J Roentgenol. 1982 Dec;139(6):1083-8. doi: 10.2214/ajr.139.6.1083.

Abstract

The radiographs, arthrograms, and bone scans in 23 patients with surgically confirmed failed total-surface hip replacement were reviewed. Guidelines for evaluation of the acetabular component are identical to those for conventional total arthroplasty. The femoral component of a surface-replacement total hip arthroplasty consists of a metallic cup affixed to a resurfaced femoral head with interposed methyl methacrylate. Because of bone-acrylic interface is obscured by the metallic cup, the radiographic features of loosening are limited to an abnormal alignment of the metallic cup in relation to the femoral neck or a change in the position of the cup in serial radiographs. These signs may be subtle. While the metallic cup may often prevent visualization of underlying isotope activity at the bone-acrylic interface, increased activity at the base of the cup when identified suggests loosening or infection.

摘要

回顾了23例经手术证实全髋关节表面置换失败患者的X线片、关节造影和骨扫描。髋臼组件的评估指南与传统全关节置换术相同。表面置换全髋关节置换术的股骨组件由一个金属杯组成,该金属杯通过甲基丙烯酸甲酯固定在经表面处理的股骨头。由于金属杯遮挡了骨-丙烯酸界面,松动的X线特征仅限于金属杯相对于股骨颈的异常排列或系列X线片中杯位置的变化。这些征象可能很细微。虽然金属杯常常会妨碍观察骨-丙烯酸界面下的同位素活性,但当发现杯底部活性增加时提示松动或感染。