A 22-mm outside diameter screw cap test tube was modified for measuring the redox potential (Eh) of samples of anaerobic media. The screw cap was fitted with a grey butyl rubber septum with a hole through which a platinum-calomel combination electrode was inserted. The tube was shortened in length and a small side arm that could be sealed with a serum stopper and an aluminium seal was attached. This device enabled the measurement of Eh of anaerobic media without the need for continuous flushing of the vessel headspace to maintain anaerobiosis.

摘要

一个外径为22毫米的螺帽试管经过改装,用于测量厌氧培养基样品的氧化还原电位(Eh)。螺帽上装有一个带孔的灰色丁基橡胶隔膜,通过该孔插入一个铂-甘汞组合电极。试管长度缩短,并连接了一个可以用血清瓶塞和铝封密封的小侧臂。该装置能够测量厌氧培养基的Eh,而无需持续冲洗容器顶部空间以维持厌氧状态。