Blair I A, Barrow S E, Waddell K A, Lewis P J, Dollery C T
Prostaglandins. 1982 Apr;23(4):579-89. doi: 10.1016/0090-6980(82)90118-6.
A highly specific stable isotope dilution assay for plasma 6-oxo-prostaglandin F1 alpha has been developed. The method employs capillary column gas chromatography coupled with negative ion chemical ionisation mass spectrometry. The limit of sensitivity of the assay is 0.5 pg.m1(-1). Concentrations of 6-oxo-prostaglandin F1 alpha in the plasma of 20 healthy volunteers determined by this assay were all below 3 pg.m1(-1). The levels were much lower than any previously reported and confirms that prostacyclin is not a circulating hormone in man under normal physiological conditions.
已开发出一种用于血浆6-氧代-前列腺素F1α的高特异性稳定同位素稀释测定法。该方法采用毛细管柱气相色谱与负离子化学电离质谱联用。该测定法的灵敏度极限为0.5 pg·m1(-1)。用该测定法测定的20名健康志愿者血浆中6-氧代-前列腺素F1α的浓度均低于3 pg·m1(-1)。这些水平远低于先前报道的任何水平,并证实前列环素在正常生理条件下不是人体中的循环激素。