Sore throat after operation: influence of tracheal intubation, intracuff pressure and type of cuff.

作者信息

Jensen P J, Hommelgaard P, Søndergaard P, Eriksen S

出版信息

Br J Anaesth. 1982 Apr;54(4):453-7. doi: 10.1093/bja/54.4.453.

Abstract

One hundred and eighty-four patients were studied to elucidate the contribution of intracuff pressure and cuff type to the occurrence of sore throat and hoarseness after operation. The patients were allocated to one of the following groups: A = mask only; B = reusable Rüsch tube with intermittent cuff volume adjustment; C = reusable Rüsch tube without cuff volume adjustment; D = disposable Portex Blue Line tube with intermittent cuff volume adjustment; E = disposable Shiley Low Pressure tube with intermittent cuff volume adjustment. Nitrous oxide was a component of anaesthesia in all patients. Moderate or severe symptoms were recorded in 30-33% of the patients in groups C, D and E, contrasting with group B, in which these sequelae were seen in only 10% of patients (P less than 0.025). All sequelae occurred less frequently in group A than in any of the other groups (P less than 0.025). Women were more likely to develop sore throat after intubation than were men (P less than 0.01). A possible relationship between differences in cuff-trachea contact area is postulated.

摘要

对184例患者进行了研究,以阐明套囊内压力和套囊类型对术后咽痛和声音嘶哑发生率的影响。患者被分为以下几组:A组 = 仅使用面罩;B组 = 可重复使用的Rüsch管,间歇性调整套囊容积;C组 = 可重复使用的Rüsch管,不进行套囊容积调整;D组 = 一次性使用的Portex蓝线导管,间歇性调整套囊容积;E组 = 一次性使用的Shiley低压导管,间歇性调整套囊容积。所有患者麻醉均使用氧化亚氮。C组、D组和E组中30%-33%的患者出现中度或重度症状,与之形成对比的是,B组中只有10%的患者出现这些后遗症(P<0.025)。A组中所有后遗症的发生率均低于其他任何一组(P<0.025)。女性插管后发生咽痛的可能性高于男性(P<0.01)。推测套囊与气管接触面积的差异可能存在某种关系。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验